Reports until 22:18, Monday 16 February 2015
H1 SYS (IOO, SEI, SUS)
jameson.rollins@LIGO.ORG - posted 22:18, Monday 16 February 2015 (16748)
Select guardian nodes left running new guardian version

The IMC_LOCK and ITMX SUS and SEI guardain nodes are running the new guardian and cdsutils release candidates.  All upgraded nodes have been test driven and appear to be functioning nominally.

The current guardian/cdsutils release candiates are:

The following nodes are running the above versions:

This has been accomplished by creating the following file in the node run directories on h1guardian0:

controls@h1guardian0:~ 0$ cat /etc/guardian/nodes/SUS_ITMX/local-env
export PATH=/bin:/usr/bin
export LD_LIBRARY_PATH=
export PYTHONPATH=
. /ligo/apps/linux-x86_64/epics/etc/epics-user-env.sh
. /ligo/apps/linux-x86_64/nds2-client/etc/nds2-client-user-env.sh || true
. /ligo/apps/linux-x86_64/cdsutils-434/etc/cdsutils-user-env.sh
. /ligo/apps/linux-x86_64/guardian-1344/etc/guardian-user-env.sh
ifo='ls /ligo/cdscfg/ifo'
site='ls /ligo/cdscfg/site'
export IFO=${ifo^^*}
export NDSSERVER=${ifo}nds0:8088,${ifo}nds1:8088
controls@h1guardian0:nodes 0$ cat /etc/guardian/nodes/SUS_ITMX/run
#!/bin/bash
set -e
exec 2>&1
if [ -e local-env ] ; then
  . local-env
elif [ -e /etc/guardian/local-env ] ; then
  . /etc/guardian/local-env
fi
exec chpst -e env guardian $(cat guardian) "$@"
controls@h1guardian0:~ 0$

The nodes were then restarted with guardctrl as normal:

controls@h1guardian0:~ 0$ guardctrl restart SUS_ITMX

The local-env files can be removed, and the nodes will be restarted to their pre-upgrade versions (guardian: r1102, cdsutils: r366).

I will proceed with a full system upgrade first thing in the morning.