ISS Maintenance

While running DBB scans this morning I noticed the ISS diffracted power was up around 12.2%.  I adjusted the RefSignal from 2.08V to 2.13V, bringing the diffracted power to 7.4%.  Running a trend shows the diffracted power started increasing slowly early Sunday morning (see attached).

Images attached to this report