Reports until 09:56, Wednesday 18 February 2015
H1 PSL (DetChar, PSL)
jason.oberling@LIGO.ORG - posted 09:56, Wednesday 18 February 2015 (16792)
ISS Maintenance

While running DBB scans this morning I noticed the ISS diffracted power was up around 12.2%.  I adjusted the RefSignal from 2.08V to 2.13V, bringing the diffracted power to 7.4%.  Running a trend shows the diffracted power started increasing slowly early Sunday morning (see attached).

Images attached to this report