Search criteria
Section: H2
Task: TCS

REMOVE SEARCH FILTER
SEARCH AGAIN
Reports until 17:23, Wednesday 05 November 2025
H1 TCS (TCS)
corey.gray@LIGO.ORG - posted 17:23, Wednesday 05 November 2025 (87985)
TCS Monthly Trends (FAMIS #28466)

Attached are monthly TCS trends for CO2 and HWS lasers.  (FAMIS link)

NOTE:  The change for ITMx HWS is due to its SLED being swapped on Oct 7 (alog 87353).

Images attached to this report
H1 TCS (TCS)
corey.gray@LIGO.ORG - posted 11:04, Wednesday 03 September 2025 (86714)
TCS Chiller Water Level Top-Off (Bi-Weekly, FAMIS #27823)

Addressed TCS Chillers (Wed [Sept3] 957-1040am local) & CLOSED FAMIS #27823:

Had a little bit of a rigmarole since I hadn't done this for a while.  In my quick procedure scan, I didn't see how to read the "floating red ball" in the chillers.  I had remembered using the bottom of the ball, but wasn't sure, so I consulted Camilla & TJ.  I ended up using the bottom for my initial measurements, but later learned we measure the top of the ball!  Either way, they were a little low, but I overfilled them since I used the bottom of the ball for readings.  Also not clear what exactly is the "Max level" (reason for overfill).  Either way, chillers had received water since June, so adding water an ok thing!  :)  Attached is a photo of what I'm talking about, and the red ball is about 4mm in diameter so I updated readings I initially entered when filling by adding 4mm to all water level readings.

Images attached to this report
H1 TCS (TCS)
corey.gray@LIGO.ORG - posted 18:08, Tuesday 12 August 2025 (86332)
TCSy CO2 Laser Drops H1 From Observing

Just had a couple of drops from Observing due to TCS_ITMY_CO2 guardian saying laser is unlocked and needed to find a new locking point.  (Attached are the two occurrences thus far).

Images attached to this report
H1 TCS (TCS)
ibrahim.abouelfettouh@LIGO.ORG - posted 16:44, Friday 08 August 2025 (86272)
TCS Monthly Trends - FAMIS 28463

Closes FAMIS 28463. Last checked in alog 85690.

CO2 Trends:

HWS FAMIS:

Plots attached

Images attached to this report
LHO General
ryan.short@LIGO.ORG - posted 07:46, Tuesday 05 August 2025 - last comment - 10:37, Wednesday 06 August 2025(86191)
Ops Day Shift Start

TITLE: 08/05 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 12mph Gusts, 6mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.09 μm/s
QUICK SUMMARY: H1 has been locked for 17 hours, but looks like there were three brief drops from observing between 11:33 and 11:40 UTC (I'm assuming SQZ-related, but will look into it). Magnetic injections are running and in-lock charge measurements will happen right after before maintenance begins at 15:00 UTC.

Comments related to this report
ryan.short@LIGO.ORG - 09:36, Tuesday 05 August 2025 (86196)

Lockloss happened during in-lock charge measurements, specifically during the 12Hz injection to ETMX. The lockloss tool tags IMC for this one, and it certainly looks like the IMC lost lock first, but I can't say for sure why.

camilla.compton@LIGO.ORG - 14:18, Tuesday 05 August 2025 (86209)TCS

The three drops from Observing that Ryan points out were actually from the CO2 lasers loosing lock, first CO2Y and then CO2X lost lock twice, all between 11:33 and 11:40UTC ~4:30amPT. Both PZTs and laser temperatures started changing ~5minutes before CO2Y last lock. Unsure what would make this happen, LVEA temperature and chiller flowrates as recorded in LVEA were stable, see attached.

Unsure of the reason for this, especially as they both changed at the same time but are for the most part independent systems (apart from shared RF source). We should watch to see if this happens again.

Images attached to this comment
thomas.shaffer@LIGO.ORG - 10:37, Wednesday 06 August 2025 (86221)TCS

My initial thought was RF, but the two channels we have to monitor that both looked okay around that time. About 4 minutes before the PZTs start to move away there is maybe a slight change in the behavior of the H1:ISC-RF_C_AMP10M_OUTPUTMON channel (attachment 1), but I found a few other times it has similar output and the laser has been okay, plus 4 minutes seems like too long for a reaction like this. The pzts do show some type of glitching behavior 1-2 minutes before they start to drive away that I haven't found at other times (attachment 2). This glitch timing is identical in both laser's pzts.

I trended almost every CO2 channel that seemed worthwhile, I looked at magnetometers, LVEA microphones, seismometers, mainsmon, and I didn't find anything suspicious. The few people on site weren't in the OSB. Not sure what else to look for at this point. I'm wondering if maybe this is some type of power supply or grounding issue, but I'd expect to see it other places as well then. Perhaps places I just haven't found yet.

Images attached to this comment
H1 General (Lockloss, TCS)
ryan.crouch@LIGO.ORG - posted 21:04, Sunday 13 July 2025 - last comment - 21:39, Sunday 13 July 2025(85730)
Lockloss 04:00 UTC

TCS CO2Y tripped and dropped us out of Observing at 03:58 UTC then we lost lock 2 minutes later, lockloss. The lockloss appears to have been an ETMX glitch.

Comments related to this report
ryan.crouch@LIGO.ORG - 21:39, Sunday 13 July 2025 (85731)

Following the WIKI and TJ's instructions I went into the LVEA (TJ was my phone buddy) to restart the controller than I went into the mechanical room and reset the power supply which was reading a current and voltage of 0 when I arrived. There were no flow/chiller alarm nor RTD/IR sens alarm.

H1 TCS (TCS)
ibrahim.abouelfettouh@LIGO.ORG - posted 19:28, Wednesday 09 July 2025 (85663)
TCS Chiller Water Level Top Off - FAMIS 27819

Closes FAMIS 27819. Last checked in alog 85440

CO2Y:

Before: 10.3ml

After: 10.3ml

Water Added: 0ml

CO2X:

Before: 30.4ml

After: 30.4ml

Water Added: 0ml

 

No water leaking in our leak detection system (aka dixie cup)

LHO General
corey.gray@LIGO.ORG - posted 07:39, Thursday 03 July 2025 - last comment - 08:49, Thursday 03 July 2025(85518)
Thurs DAY Ops Transition

TITLE: 07/03 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 5mph Gusts, 2mph 3min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.07 μm/s
QUICK SUMMARY:

H1 had (3)  ~2-hr locks overnight (looks like no wake-up calls for Oli!).  H1 is currently locking (just powered up to 25W).  Winds stepped down at about 130amPDT (837utc).

Today is Thurs Commissioning from 8am-12pmPDT (15-19utc).  H1 won't be thermalized until about 1030-11amPDT, so no calibration...hopefully H1 short locks won't be an issue for calibration where we need H1 thermalized 3hrs.  Robert and Sheila will probably start their work

Comments related to this report
elenna.capote@LIGO.ORG - 08:23, Thursday 03 July 2025 (85520)

Just want to add a note that all three locks from last night were nearly the exact same length, 1:51, and the locklosses are all tagged with "PI monitor". A ring heater was changed yesterday, 85514, which may have caused this problem.

corey.gray@LIGO.ORG - 08:29, Thursday 03 July 2025 (85521)SUS, TCS

Additionally, each of the 3 locklosses were from PI28/29 according to VerbalAlarms (the Ring Heater change yesterday was made to address PI24 which riddled our 7hr lock for the last hour before the ultimate lockloss).

elenna.capote@LIGO.ORG - 08:49, Thursday 03 July 2025 (85522)

While we have been running PIMON live on nuc25, it appears the data from the lockloss hasn't been saved. The newest file in the /ligo/gitcommon/labutils/pimon/locklosses folder is from December 2024. I'm not sure what's going on. We think our problem is an 80 kHz PI, so this would be useful data to have.

H1 CDS
david.barker@LIGO.ORG - posted 15:52, Tuesday 01 July 2025 - last comment - 07:53, Friday 11 July 2025(85482)
Early report on HWS cameral control

Camilla, TJ, Dave:

Last Thursday 26th June 2025 alog85373 I restarted the HWS camera control code. We hoped this would improve the 2Hz noise comb in DARM. Initial results for F-Scan (observing) suggest it has not made much, if any difference. 

Attached F-Scans show the spectra on sun22jun2025 and mon30jun2025. The 2Hz comb (blue squares) look unchanged.

More investigation is needed to verfiy we are indeed disabling the frame aquisition on all HWS cameras when H1 is in observation.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 16:33, Thursday 10 July 2025 (85678)DetChar, TCS

Looking at the HWS camera data, Dave's code was successfully stopping the HWS camera dueing NLN from 27th June, as expected 85373.

However, looking at the f-scans from the last week, the 2Hz comb was there until 3rd July but was gone on 4th July and hasn't returned since.

Nothing HWS related should have changed on the 3rd July (ops shift log 85519).

Images attached to this comment
evan.goetz@LIGO.ORG - 07:53, Friday 11 July 2025 (85683)DetChar
Excellent, thank you Camilla and Dave! This is very helpful.
H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 10:54, Wednesday 25 June 2025 - last comment - 13:47, Wednesday 25 June 2025(85327)
Lockloss

Lockloss during commissioning at 2025-06-25 17:52UTC after over 5.5 hours Locked. Cause not known, but probably not commissioning related.

Comments related to this report
oli.patane@LIGO.ORG - 12:56, Wednesday 25 June 2025 (85334)

18:48 Back to NOMINAL_LOW_NOISE

camilla.compton@LIGO.ORG - 13:47, Wednesday 25 June 2025 (85335)TCS

Within the same ~15 seconds of the lockloss, we turned the CO2 powers down form 1.7W each to 0.9W each. In the hope of doing the thermalization tests we tried last week 85238.

We checked the lockloss today and LSC channels at the time last week we turned the CO2s down and see no glitches corresponding with the CO2 waveplate (out of vac) change, we think the lockloss was unrelated.

H1 ISC (SQZ, TCS)
camilla.compton@LIGO.ORG - posted 08:51, Monday 09 June 2025 (84894)
ISCT1 Bellows Back on, all LVEA lasers back on.

TJ, Camilla WP 12605WP 12593

As HAM1 is now low enough in pressure, we removed the HAM1 +Y yellow VP covers, re-attached bellows and removed guillotines. ISCT1 was moved back into place on Friday 84850.

After TJ transitioned to Laser Hazard, we opened the ALS and PSL light pipes and turned back on the SQZ, CO2s and HWSs lasers.  

After okay from VAC, IMC locked without issue, PRC and MICH alignments look good enough on AS AIR camera and we will begin realigning ISCT1 soon.

H1 CDS (CDS, TCS)
erik.vonreis@LIGO.ORG - posted 12:39, Friday 06 June 2025 (84865)
HWS data files moved

HWS servers now point to /ligo/data/hws as the data directory.

The old data directory, h1hwsmsr:/data, is now moved to h1hwsmsr:/data_old

The contents of the old directory were copied into the new directory, except H1/ITMX, H1/ITMY, H1/ETMX, H1/ETMY, under the assumption that these only contain outputs from the running processes.

HWS processes on h1hwsmsr, h1hwsmsr1, h1hwsex were stopped and restarted and are writing to the new directory.

h1hwsey had crashed previously and wasn't running.  It was restarted and is also writing to the new directory

H1 TCS (TCS)
corey.gray@LIGO.ORG - posted 13:55, Monday 02 June 2025 (84721)
TCS Chiller Water Level Top-Off (Bi-Weekly, FAMIS #27816)

Addressed TCS Chillers (Mon [Jun2] 100-125am local) & CLOSED FAMIS #27816:

H1 ISC (TCS)
camilla.compton@LIGO.ORG - posted 13:47, Monday 14 April 2025 (83901)
Checking Return EY ALS beam with QPD offsets on and off.

TJ, Sheila, Matt, Andrew (job shadow today), Camilla. WP12433. Table layout D1400241.

Following on from other beam profile work at the end stations 81358, Madi Simmonds models G2500646 and the ideas we had for understanding ETM mode matching better (googledoc), today we took some beam profiles of the EY ALS beam reflected of ETM HR in the HWS path.

We added a 532nm quarter waveplate downstream of the beamspiltter (ALS-M11) and tuned it to maximize the light reflected into the HWS path. This was removed when we were finished and left with Nanoscan beam profile.

We first took some beam profile measurements (photos 1-4) first with the QPD offsets on nominally, and then with the offsets zero'ed (phots 5-9). Unless the beam has been pico-ed (which it may have) the zero offsets should have the beam more centered on the Transmon parabolic mirrors. The beam changed when the offsets were turned off but did not look better/worse, just different. Compare photo 4 (QPD offsets on) and photo 5 (offsets off).

Photo
#
 
A1 horizontal
13.5%
A2 vertical
13.5%
A1 horizontal
50%
A2 vertical
50%
Started with QPDs on at thier usual values:
1
50.5cm downstream of HWS-M3 (between M3 and M4)
1485
1685
723
871
2
42.5cm downstream of HWS-M3 (between M3 and M4)
1783
1985
877
970
3
36.5cm downstream of HWS-M3 (between M3 and M4)
1872
2146
924
1135
4
13.0cm downstream of HWS-M3 (between M3 and M4)
2540
2991
1247
1516
Then we turned off QPD offsets and retook data:
9
51cm downstream of HWS-M3 (between M3 and M4)
1370
1570
676
853
8
33.5cm downstream of HWS-M3 (between M3 and M4)
1939
2184
959
1086
7
48.5cm downstream of HWS-M3 (between M3 and M4)
1440
1655
706
876
6
36cm downstream of HWS-M3 (between M3 and M4)
1830
2130
913
1098
5
13.0cm downstream of HWS-M3 (between M3 and M4)  
2186
2861
1045
1077
Images attached to this report
H1 TCS (TCS)
ibrahim.abouelfettouh@LIGO.ORG - posted 12:36, Thursday 03 April 2025 (83726)
TCS Chiller Water Level Top Off - FAMIS 27812

Closes FAMIS 27812. Last checked in alog 83486

CO2Y:

Before: 10.4ml

After: 10.4ml

Water Added: 0ml

CO2X:

Before: 30.1ml

After: 30.1ml

Water Added: 0ml

 

No water leaking in our leak detection system (aka dixie cup)

H1 ISC (CAL, ISC, TCS)
jeffrey.kissel@LIGO.ORG - posted 12:31, Thursday 20 March 2025 (83468)
9.75 kHz to 10.75 kHz ASD of OMC DCPD A during Nominal Low Noise, Calibrated in OMC DCPD TEST DAC Drive
J. Kissel

I've been tasked with using the analog voltage input to the OMC DCPD transimpedance amplifiers (LHO:83466) to drive a sine wave around 10 kHz, in order to try to replicate a recent PI ring up which apparently caused broad-band low frequency noise LHO:83335.

There is a remote excitation channel that typically drives the this analog input excitation path is running at 16 kHz: the H1:OMC-TEST_DCPD_EXC channel's filter module lives in the h1lsc.mdl model in a top_names OMC block at the top level of the model, and the output of that filter bank is connected to the lsc0 IO chassis' DAC_0's 11th / 12th digital/analog channel. That DAC's AI channel goes through quite an adventure before arriving at the OMC whitening chassis input -- following D19000511,
    - AI chassis for lsc0 IO chassis DAC_0 lives in ISC-C1 U7, port OUT8-11 D9M spigot (page 2, component C15), connected to cable ISC_406
    - The long ISC_406 DB9 cable connects to a LEMO Patch Panel (D1201450) on the other end in ISC-R5 U12 (page 22, component C210).
    - Funky LEMO to D9M cable D2200106 ISC_444 connects from the patch panel to the whitening chassis,
    - ISC_444 D9F end of the cable to lands at the  J4 D9M port labeled "From AI/DAC / Test Inputs" of OMC DCPD whitening chassis in U24 of ISC-R5 rack.

... but this won't work: this channel is driven at 16 kHz sampling frequency. So, we can't drive anything technically above 8192 Hz, but realistically above ~5-6 kHz.
I digress.

I'm going with SR785 excitation via DB9 breakout.

Anyways -- I attach here an ASD of the OMC DCPDs sampled at 524 kHz during nominal low noise this morning (taking advantage of the live-only 524 kHz channels), low-passed at 1 Hz, without any digital AA filters; the channel H1:OMC-DCPD_524K_A1 filter banks channels from LHO:82686. The OMC DCPD z:p=1:10 Hz whitening is ON during nominal low noise.

The top panels show a zoomed in, and zoomed out version of the DCPDA ASD calibrated into photocurrent on the PDs (H1:OMC-DCPD_524K_A1_OUT channel, * 0.001 [A/mA], all the rest of the calibration is built in to the front-end filter bank; see OUT DTT Calibration).
The bottom panels show a zoomed in, and zoomed out version of the DCPD ASD calibrated into ADC input voltage, with what whitening that was ON divided out, and the 2x ~11 kHz poles of the TIA divided out. (H1:OMC-DCPD-524K_A1_IN channel, * 1/4 [four-channel copy sum to avg conversion] * 0.0001526 [V/ct for 40 Vpp range over an 18 bit ADC] * z:p = (10):(1) inverse whitening filter * z:p = (11k,10k):([]) inverse HF TIA response )

In the zoomed in version of the plots, you can clearly see the mess of acoustic modes at 10.4 kHz. 
One can also see relatively noise free region at 10.3 kHz that looks clean enough for me to target with my analog excitation.

I plot the de-whitened ADC voltage because the transfer function between the TEST DAC input and the TIA's output voltage is designed to the 1.0 in the GW band, from ~50 to 5 kHz, given that in that band, the transimpedance is 100e3 [V/A] and the series resistor that turns the voltage injection of the TEST input into current is 100e3 [V/A] (see ). So "nominally" un-whitened ADC counts should be a one-to-one map to DAC voltage input. At 10 kHz, however, the 2x ~11 kHz poles of the TIA, which drop the TEST input voltage by a factor of 5x at 10 kHz (see, e.g. plots from LHO:78372)

So, that's why in the lower panels of the above mentioned plot of OMC DCPD A's ADC voltage calibrated in the way mentioned above. This should be a one-to-one map to the equivalent DAC voltage to drive.

I looks like the non-rung-up 10.4 kHz PI modes today were of-order 1e-2 V = 10 mV, and the surrounding noise floor is around 1e-5 V = 10uV = 0.01 mV of equivalent DAC drive.

The lower limit of the SR785 SRC amplitude is 0.1 mVp = 0.2 mVpp (single ended).
Also, using the SR785 in a FFT measurement mode, where you can drive the source at a single frequency, there is no ramp. It's just ON and/or OFF.
(I should also say that a SR DS340 function generator also doesn't have a ramp on its output. I considered using that too.)

So -- hopefully, suddenly turning on a noisy 10.3 kHz line at 0.1 mVp into the IFO with a noise floor of 0.01 mV/rtHz at 10kHz won't cause problems, but ... I'm nervous.


Images attached to this report
H1 TCS (TCS)
ibrahim.abouelfettouh@LIGO.ORG - posted 14:29, Friday 07 March 2025 (83234)
TCS Monthly Trends - FAMIS 28458

Closes FAMIS 28458. Last checked in alog 82659.

Images attached to this report
H1 TCS (TCS)
corey.gray@LIGO.ORG - posted 17:51, Wednesday 05 February 2025 - last comment - 09:41, Monday 10 February 2025(82659)
TCS Monthly Trends (FAMIS #28457)

Attached are monthly TCS trends for CO2 and HWS lasers.  (FAMIS link)

Comments related to this report
corey.gray@LIGO.ORG - 09:41, Monday 10 February 2025 (82717)TCS

Whoops!  Forgot to attach the actual trends!! (thanks for catching this, Camilla!)  Attachements are now attached!

Images attached to this comment