Displaying report 1-1 of 1.
Reports until 11:52, Monday 23 February 2015
H1 SUS
betsy.weaver@LIGO.ORG - posted 11:52, Monday 23 February 2015 - last comment - 11:54, Monday 23 February 2015(16863)
Extra offsets on ETMx investigated

A late entry with data:  It doesn't look like the ETMx offsets that Keita (alog 16591) implemented in an attempt to decouple the large pitch of the main chain from the reaction chain was doing much.

Attached are Pitch transfer functions of the top, middle, and lower stages of the ETMx comparing various times when the large pitch bias and the Keita offsets were on and off.  Not much change in any of the configurations in any of the 3 stages of the ETMx.  Note, according to Jeff's alog 16824, the Keita offsets were all turned off last Thur night.

Images attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 11:54, Monday 23 February 2015 (16866)

Attached are TFs of the ETMx L1 and L2 stages showing the large pitch bias effect as seen by the OSEMs.

Images attached to this comment