Displaying report 1-1 of 1.
Reports until 12:16, Monday 23 February 2015
H1 SEI (ISC)
hugh.radkins@LIGO.ORG - posted 12:16, Monday 23 February 2015 (16869)
HEPI trip on ETMX last night ~2210pst---ISC caused

Attached is 5 seconds of full data where the ISC sent a whole bunch (5e5nm) of LONG output to the HEPI all at once.  The fast channels (shown on HPI ISO X) triggered the HEPI watchdog and the slow channels never see a thing.  Why would ISC do such a thing?

Images attached to this report
Displaying report 1-1 of 1.