Reports until 15:55, Monday 23 February 2015
H1 PSL (PSL)
nutsinee.kijbunchoo@LIGO.ORG - posted 15:55, Monday 23 February 2015 (16872)
PSL Check
Laser Status: 
SysStat is good
Output power is 28.7 W (should be around 30 W)
FRONTEND WATCH is RED
HPO WATCH is RED

PMC:
It has been locked 1 day, 2 hr 34 minutes (should be days/weeks)
Reflected power is 2 Watts  and PowerSum = 24.4 Watts.
(Reflected Power should be <= 10% of PowerSum)

FSS:
It has been locked for 0 h and 44 min (should be days/weeks)
Threshold on transmitted photo-detector PD = 0.70 V (should be 0.9V)

ISS:
The diffracted power is around 13.8% (should be 5-15%)
Last saturation event was 1 d 2 h and 4 minutes ago (should be days/weeks)