Displaying report 1-1 of 1.
Reports until 17:36, Monday 23 February 2015
H1 ISC
gabriele.vajente@LIGO.ORG - posted 17:36, Monday 23 February 2015 (16875)
We need an ASC loop for SRM

Comparisng two stretches of lock that Dan pointed to me (one from Friday, good stable  sensitivity, and one from last night, worse sensitivity), I find a clear non-stattonary behavior of the sensitivity, see the first two plots, which are spectrograms of ten minutes of data during each lock.

Analyzing last night's lock, I computed the band-limited RMS between 100 and 300 Hz and it indeed shows an almost regular oscillation at about 120-140 mHz. I compared this oscillation with few auxiliary channels, and found out good correlation with the SRM angular motion (third plot), and expecially with AS_RF36 WFS signals (fourth plot).

The last two plots show my usual least square fit of the BLRMS using a set of auxiliary channels:

In summary, I think we need to commission an angular control for the SRM, and it seems we have good signals from AS_RF36. The main motion is in pitch.

Images attached to this report
Displaying report 1-1 of 1.