[Stuart A, Jeff K] After yesterday’s preparation and discussion (see LHO aLOG entries 16874 and 16868), this morning we completed the roll-out with the aim of providing AS WFS damping of roll modes, for all QUADs, as follows: (1) LSC, OMC and ASC models were restarted (see LHO aLOG entry 16893), which enabled the necessary IPC/RFM senders. However, there were some channel name changes to deal with... (2) ETMs H1:LSC-ETMX_DARM_ERR renamed to H1:OMC-ETMX_DARM_ERR (same goes for ETMY). (3) ITMs H1:LSC-OAF_DARM_ERR renamed to H1:LSC-ETMX_DARM_ERR (originated from LLO using the calibrated version of DARM ERR for ITMs and raw for ETMs). (4) Svn'd up the common MEDM screens (after remotely committing them from LLO): /opt/rtcds/userapps/trunk/sus/common/medm/quad/ U SUS_CUST_QUAD_M0_DAMP_MATRIX.adl U SUS_CUST_QUAD_M0_DAMP_MODE.adl U SUS_CUST_QUAD_OVERVIEW.adl (5) Removed LLO's Tidal implementation from the Overview Screen (see LLO aLOG entry 16753). (6) Rebuilt, installed and restarted the h1susetmx, h1susetmy, h1susitmx, h1susitmy models. (7) Noticed some white boxes on Overview Screen, which were site specific to L1, so I fixed these with a $(IFO) substitution and re-committed SUS_CUST_QUAD_OVERVIEW.adl to the svn. Screen-shots below show the updated MEDM screens. This should help inform ECR E1500090 and Integration Issue #1015, in determining which AS WFS channels are most suitable for damping QUAD roll modes at each site.