04:57 Turned on the HEPA fans in the H1 PSL Laser Room. I would like to run this test for at least a couple of hours. It is noticeable that as soon as the fans are turned on, the minimum and maximum values of the ISS percent diffraction vary by ~1%. 06:55 Turned off HEPA fans. In running this test, I had forgotten that running the HEPA fans generates heat, and is not a good idea without turning on the air conditioning. I switched on the air conditioning to bring the temperature back down and switched it off after about 40 minutes. Attached is the output of the quadrant photodiode that is located inside the power stabilisation photodiode box. Assuming that DY is vertical and DX is horizontal, it appears that the vertical alignment does not recover, whilst the horizontal alignment does. Also attached is the reference cavity transmission signal during the same period. It seems to recover.