Reports until 19:16, Friday 27 February 2015
H1 ISC
eleanor.king@LIGO.ORG - posted 19:16, Friday 27 February 2015 - last comment - 09:31, Friday 06 March 2015(16993)
Locking SRMI

Kiwamu, Dave, Evan, Betsy, Elli

Today we locked SRMI in preparation for measuring the SRCL guoy phase.  The lock is not particularly robust, but we are hoping it will be good enough to takea preliminary measurement...

Initial settings:

MICH is locked to LSC-ASAIR_A_LF with input matrix value 0.25, a H1:LSC-MICH_OFFSET offset of -200, a gain of H1:LSC-MICH_GAIN 1600 (or locking with  gain 800 then ramping up to 1600 also works), and an output matrix value of 1 going to BS. FM7 (zpk([1],[150;75+i*129.904;75-i*129.904,1,"n")) and FM9  (ELP40) are on in the MICH loop.

SRCL is locked to LSC-REFLAIR_RF9_I with an input matrix value -3.75, H1:LSC-SRCL_GAIN gain of -50000, a SRCL offset of 0 and an output matrix value of 1 going to SRM.  FM9 (zpk([10],353.553+i*353.553;353.553-i*353.553,1,"n")gain(10)) and FM10 (cheby1('LowPass",2,1,300)) are on in the SRCL loop.

Trigger settings are:

MICH: triggered by ASAIR_A_DC gain 1, upper thereshhold 1000, lower threshold 400.  Filter trigger thresholds On:1000 Off:400, 1seconds, FM2 triggered. (FM2 is zp1:0)

SRCL: triggered by ASAIR_A_DC  gain 1, upperthreshold -1000 lower threshold -1000.  Filter trigger threshold On:400 Off:400, 0.2seconds, FM2 and FM3 triggered. (FM2 is zp1:0 FM3 is zpk([1],[0.1],10,'n')resgain(0.684,3,10).)

Aquiring lock:

We are kind of triggreing the whole thing manually by setting up the above initial settings, and then turning off H1:LSC-CONTROL_ENABLE so no control signals are passed from the LSC output matrix to the suspensions.  If we don't do thisthe optics get kicked around and we don't lock.  We wait untill the AS_AIR flashes look slow (~1Hz) and then turn on H1:LSC-CONTROL_ENABLE.  About 20% of the time we then aquire lock (or we try again).  It is taking <1min to lock.

After aquiring lock:

Engage FM4 (zp 4:0).  Lock stretches are lasting for a few minutes  in this configuration, longest locks~10 mins.

Also: 

-The MICH bounce mode keeps ringing up at 17Hz so we have been damping it every now and then using by turning H1:SUS-BS_M2_VRDAMP_P filter.

-Flashes of SRMI were reaching the H1:ASC-OMC_A/B qpds which was moving OM3.  We disabled the feedback to OM3 by setting the H1:OMC-ASC_POS gains to zero. These gains have been returned to their previous values.

Comments related to this report
eleanor.king@LIGO.ORG - 09:31, Friday 06 March 2015 (17090)

Some extra settings I forgot to mention:

H1:SUS-BS_M3_ISCINF_L_LIMIT is on, set to 500000.

IMC input power was 5W. (Set H1:PSL-POWER_SCALE_OFFSET to 5!)

SRM M2 lock L stage needs to be turned off during lock aquisition.

Initial settings:

MICH: FM7 (150^3:1  ,  zpk([1],[150;75+i*129.904;75-i*129.904,1,"n")) FM9 (ELP40)

SCRL: FM9 (cntrl  ,  zpk([10],353.553+i*353.553;353.553-i*353.553,1,"n") FM10 (CLP300, cheby1('LowPass",2,1,300)), GAIN WAS ACTUALLY -40000!

Turned of SCA master gain switch.

After aquiring lock:

Ramp gain of MICH loop to 1600 (if not already there) and engage FM4.  (I stopped doing this after a while.  Not sure it's helping much.)

(When turning stuff off:  set H1:LSC-PD_DOF_MTRX_RAMPING_3_25 H1:LSC-PD_DOF_MTRX_RAMPING_3_25 (MICH intrix) to zero, return laser to 2.8W.)