high winds at End Y

Jim, Krishna, Ryan, Jeff, Sheila, Alexa, Evan, everyone

We have been having trouble keeping the Y arm locked with green, due to cavity motion of about 10 um in about 10 seconds.  The winds at end Y are approaching 40 mph, and have been climbing for an hour and a half.  We have copied the 90mHz blends for X and Y from the ETMX ISI into ETMY and blending high has allowed us to lock ALS for now.  

The attached screen shot shows the Y arm control signal (from the end station PDH with no slow feedback on) in beige, and the X arm in yellow.  The blends were switchd at about -21 minutes.  

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 14:53, Friday 06 February 2015 (16528)

Here are a few more PEM screenshots of the wind and what it has been doing.

Images attached to this comment
jeffrey.kissel@LIGO.ORG - 09:16, Monday 02 March 2015 (17013)
J. Kissel, S. Dwyer

For the record, Sheila only remembers changing the blend configuration for ISI ETMY, which is why only the brown trace (ALS-Y_REFL_CTRL) gets visibly better in the StripTool.