Displaying report 1-1 of 1.
Reports until 06:56, Tuesday 03 March 2015
H1 ISC (CAL, CDS, DetChar)
jeffrey.kissel@LIGO.ORG - posted 06:56, Tuesday 03 March 2015 (17032)
Turned OFF 'Undisturbed' on Guardian's Observation Intent Bit
J. Kissel

The IFO is down (and has been for ~4 hours, most likely because of the 6.4 [mag] EQ in Indonesia) and I'm beginning updates to the LSC, OMC, SUSMC2, and CALCS models to fix up the IMC/CARM calibration paths, so I've turned OFF the observation intent bit around 14:50 UTC (6:50a PT). 

I've also switched the ISC LOCK and IMC LOCK guardians to the DOWN state. I found that MC2 had not had its alignments saved, so I've saved them.
Displaying report 1-1 of 1.