J. Kissel I'll file an aLOG later about the philosophy of design as I create the MEDM screens and fill out the infrastructure, but for now I'll indicate that I've completed the model / DAQ restarts necessary to install the infrastructure updates to the IMC / CARM calibration paths in the h1lsc, h1omc, h1susmc2, and h1calcs front-end models. A detailed log of what I've done is below. I've restarted the DAQ at ~07:31 UTC. - brought ISC LOCK and IMC LOCK guardians to DOWN - saved SUS MC2 alignment offsets - brought SUS MC2 to safe state - captured and committed safe.snaps for /opt/rtcds/userapps/release/ sus/h1/burtfiles/h1susmc2_safe.snap << -- used SDF system, following instructions in LHO aLOG 16949 lsc/h1/burtfiles/h1lsc_safe.snap << -- used "makeSafeBackup lsc h1lsc" omc/h1/burtfiles/h1omc_safe.snap << -- (as above) cal/h1/burtfiles/h1calcs_safe.snap << -- (as above) - compiled and installed relevant front-end models on h1build make h1lsc; confirmed success; make install-h1lsc; confirmed success; make h1omc; confirmed success; make install-h1omc; confirmed success; make h1susmc2; confirmed success; make install-h1susmc2; confirmed success; make h1calcs; confirmed sussess; make install-h1calcs; confimed success; - h1lsc has an IPC error before getting started, but cleared and stayed clear after diag reset (no other models had IPC errors reported) - brought HAM3 SEI to OFFLINE (with a spurious GS13 watchdog trip along the way) - restarted relevant front-end code on h1lsc0 -- cdsCode; starth1lsc This lit up the CDS overview with IPC errors as expected, on h1omc, oaf, lscaux, asc, ascimc, and the globally controlled sus (the MCs 1-3, PRs M&2, SRs M&2, BS, OMs, RMs, and TMs). Decided to complete model restarts before clearing errors. on h1omc -- starth1omc on h1calcs -- starth1calcs released the model still needs new IPC senders from MC2 before its IPC errors go away on h1sush34 -- starth1susmc2 on h1oaf0 -- starth1calcs - Hand-cleared all IPC error messages with a diag reset on all affected model's GDS_TP screens; confirmed no lingering errors were present. - cleared SUS MC2 and ISI HAM3 watchdogs from SUS model restart - brought HAM3 SEI up to ISOLATED (accompanied by another spurious GS13 watchdog trip) - brought SUS MC2 to ALIGNED - brought IMC_LOCK guardian back to LOCKED, confirmed successful relock of IMC, appearance of light on AS port in the same camera position it was when I got started - shutdown DAQ / FB / h1dc0 at 07:31 UTC to clear remaining DAQ errors; confirmed the only remaining error is from h1oaf model, who is now missing some CARM / IMC senders - committed all model changes to the userapps repo, ${userapps}/lsc/h1/models$ Sending h1lsc.mdl ${userapps}/omc/h1/models$ Sending h1omc.mdl ${userapps}/sus/h1/models$ Sending h1susmc2.mdl ${userapps}/cal/common/models$ Sending CAL_CS_MASTER.mdl ${userapps}/cal/h1/models$ Sending h1calcs.mdl Committed revision 9944. DONE!