DRMI ASC work today

Gabriele, Elli, Dan, Sheila

Today we worked on ASC for DRMI + arms off resonance.  

Images attached to this report
Comments related to this report
gabriele.vajente@LIGO.ORG - 02:12, Thursday 05 March 2015 (17087)

In the past we weren't able to increase enough the bandwidth of the PRC2 loop. It was limited at maybe a maximum of ~10 mHz.

Looking at the model of the pitch and yaw actuators, it turns out that the limit is the first resonance at 1 Hz, which pops above the unity gain and make the loop unstable.

This can be easily solved if we add a double real pole at 300 mHz in the compensator, as shown in the attached sisotool design. In this way the UGF can be increased to 100 mHz, with good phase margin.