Full lock ASC sensing matrix yaw

Sensing matrix (abs)

Excitation: H1:ASC-INP1_Y_EXC H1:ASC-PRC1_Y_EXC H1:ASC-PRC2_Y_EXC H1:ASC-MICH_Y_EXC H1:ASC-SRC1_Y_EXC H1:ASC-SRC2_Y_EXC H1:ASC-DHARD_Y_EXC H1:ASC-CHARD_Y_EXC
Monitor channel: H1:ASC-INP1_Y_OUT_DQ H1:ASC-PRC1_Y_OUT_DQ H1:ASC-PRC2_Y_OUT_DQ H1:ASC-MICH_Y_OUT_DQ H1:ASC-SRC1_Y_OUT_DQ H1:ASC-SRC2_Y_OUT_DQ H1:ASC-DHARD_Y_OUT_DQ H1:ASC-CHARD_Y_OUT_DQ
H1:ASC-AS_A_DC_YAW_OUT_DQ 4.031685e-07 5.392346e-07 8.311928e-06 2.881588e-06 1.004452e-06 3.301726e-06 1.667395e-07 1.524016e-08
H1:ASC-AS_A_RF36_I_YAW_OUT_DQ 1.991316e-02 3.858034e-02 2.998611e-01 3.219276e-01 1.353022e-02 2.613919e-02 5.956869e-05 3.014351e-06
H1:ASC-AS_A_RF36_Q_YAW_OUT_DQ 1.013659e-02 8.320306e-03 5.906850e-02 1.600886e-01 1.564192e-03 3.046164e-02 2.631369e-04 4.566430e-05
H1:ASC-AS_A_RF45_I_YAW_OUT_DQ 1.661431e-03 2.121179e-03 6.452280e-03 2.210928e-02 1.743886e-03 6.018634e-03 9.055341e-04 2.395158e-04
H1:ASC-AS_A_RF45_Q_YAW_OUT_DQ 3.612030e-03 3.187511e-03 6.402889e-02 1.849432e-02 6.428634e-03 1.990436e-02 1.930394e-03 4.172696e-04
H1:ASC-AS_B_DC_YAW_OUT_DQ 1.757336e-07 6.941324e-07 8.164861e-06 4.630952e-07 1.081163e-06 5.167964e-07 1.199717e-07 1.471614e-08
H1:ASC-AS_B_RF36_I_YAW_OUT_DQ 4.313914e-03 9.863339e-03 3.969614e-02 9.370721e-02 2.542824e-03 2.871498e-02 2.469401e-04 3.410662e-05
H1:ASC-AS_B_RF36_Q_YAW_OUT_DQ 2.080965e-02 2.235516e-02 1.705056e-01 1.804781e-01 6.698143e-03 2.710248e-02 3.950121e-05 2.041372e-05
H1:ASC-AS_B_RF45_I_YAW_OUT_DQ 1.020778e-03 9.954585e-04 6.219793e-03 1.549895e-02 1.600995e-03 2.809151e-03 6.968702e-04 2.112154e-04
H1:ASC-AS_B_RF45_Q_YAW_OUT_DQ 1.365308e-03 6.034298e-04 2.545113e-02 1.160158e-02 6.862895e-03 3.255676e-03 1.580237e-03 3.007709e-04
H1:ASC-REFL_A_DC_YAW_OUT_DQ 5.887914e-05 3.642079e-06 4.864500e-06 8.840696e-07 5.707180e-08 1.118971e-07 1.920320e-09 1.760073e-08
H1:ASC-REFL_A_RF9_I_YAW_OUT_DQ 9.125244e-01 4.685791e-02 1.433883e-01 2.719587e-02 3.398776e-04 3.071677e-03 9.913482e-06 3.254621e-04
H1:ASC-REFL_A_RF9_Q_YAW_OUT_DQ 1.119344e-01 4.052422e-03 3.017529e-02 2.788209e-03 7.235137e-05 6.180180e-04 1.174930e-05 8.308296e-05
H1:ASC-REFL_A_RF45_I_YAW_OUT_DQ 3.226940e-01 1.826235e-02 2.025763e-01 5.645713e-02 1.924779e-03 8.484405e-03 1.656515e-05 2.711756e-04
H1:ASC-REFL_A_RF45_Q_YAW_OUT_DQ 7.134476e-02 8.995083e-03 1.064620e-01 2.517365e-02 2.447210e-03 9.818037e-03 4.068771e-06 1.069372e-04
H1:ASC-REFL_B_DC_YAW_OUT_DQ 7.072096e-05 1.609598e-06 3.478367e-06 3.256197e-07 4.663900e-08 6.349670e-08 1.569532e-09 8.590143e-09
H1:ASC-REFL_B_RF9_I_YAW_OUT_DQ 7.147608e-01 1.396809e-02 2.839755e-01 4.478032e-02 1.249494e-03 3.379724e-03 7.465704e-06 3.472900e-04
H1:ASC-REFL_B_RF9_Q_YAW_OUT_DQ 2.724818e-01 5.678733e-03 9.150944e-02 1.270724e-02 3.721091e-04 9.763051e-04 2.295483e-06 6.932303e-05
H1:ASC-REFL_B_RF45_I_YAW_OUT_DQ 2.846739e-01 2.667722e-02 5.800374e-02 9.514586e-03 4.868248e-04 1.040630e-03 1.751774e-05 3.269201e-04
H1:ASC-REFL_B_RF45_Q_YAW_OUT_DQ 2.082370e-02 6.591069e-03 3.520480e-02 1.409508e-02 4.185252e-04 1.431846e-03 5.608350e-06 6.566866e-05
H1:ASC-POP_A_YAW_OUT_DQ 2.329535e-07 4.373996e-07 7.104547e-07 1.840680e-07 3.540810e-09 1.446617e-08 3.051640e-10 4.730231e-09
H1:ASC-POP_B_YAW_OUT_DQ 1.624792e-07 3.356867e-07 4.080737e-07 1.022386e-07 1.532934e-09 7.861499e-09 2.480083e-10 4.031364e-09

Coherence matrix

Excitation: H1:ASC-INP1_Y_EXC H1:ASC-PRC1_Y_EXC H1:ASC-PRC2_Y_EXC H1:ASC-MICH_Y_EXC H1:ASC-SRC1_Y_EXC H1:ASC-SRC2_Y_EXC H1:ASC-DHARD_Y_EXC H1:ASC-CHARD_Y_EXC
Monitor channel: H1:ASC-INP1_Y_OUT_DQ H1:ASC-PRC1_Y_OUT_DQ H1:ASC-PRC2_Y_OUT_DQ H1:ASC-MICH_Y_OUT_DQ H1:ASC-SRC1_Y_OUT_DQ H1:ASC-SRC2_Y_OUT_DQ H1:ASC-DHARD_Y_OUT_DQ H1:ASC-CHARD_Y_OUT_DQ
H1:ASC-AS_A_DC_YAW_OUT_DQ 0.877995 0.936322 0.964207 0.964613 0.999556 0.999214 0.951342 0.366137
H1:ASC-AS_A_RF36_I_YAW_OUT_DQ 0.958806 0.981377 0.975624 0.999814 0.994314 0.988471 0.880617 0.004955
H1:ASC-AS_A_RF36_Q_YAW_OUT_DQ 0.952277 0.901434 0.820429 0.999562 0.922665 0.998616 0.942394 0.584411
H1:ASC-AS_A_RF45_I_YAW_OUT_DQ 0.933718 0.890399 0.328643 0.993219 0.993367 0.998007 0.996696 0.937408
H1:ASC-AS_A_RF45_Q_YAW_OUT_DQ 0.935617 0.830683 0.921302 0.935596 0.996761 0.998303 0.986227 0.831517
H1:ASC-AS_B_DC_YAW_OUT_DQ 0.514456 0.977653 0.982686 0.461225 0.999363 0.990782 0.973868 0.622839
H1:ASC-AS_B_RF36_I_YAW_OUT_DQ 0.813502 0.951416 0.598040 0.997792 0.952954 0.998459 0.958816 0.515462
H1:ASC-AS_B_RF36_Q_YAW_OUT_DQ 0.961435 0.962455 0.948682 0.998859 0.979631 0.993586 0.877446 0.239719
H1:ASC-AS_B_RF45_I_YAW_OUT_DQ 0.922720 0.667963 0.402587 0.991521 0.995724 0.994284 0.996490 0.945958
H1:ASC-AS_B_RF45_Q_YAW_OUT_DQ 0.854440 0.083537 0.587561 0.874576 0.997187 0.978271 0.980857 0.735839
H1:ASC-REFL_A_DC_YAW_OUT_DQ 0.994522 0.620990 0.135750 0.010622 0.009686 0.281819 0.009492 0.055766
H1:ASC-REFL_A_RF9_I_YAW_OUT_DQ 0.998993 0.839166 0.090888 0.447572 0.049205 0.759129 0.167374 0.930424
H1:ASC-REFL_A_RF9_Q_YAW_OUT_DQ 0.951957 0.447989 0.119508 0.166774 0.045552 0.587132 0.703928 0.839773
H1:ASC-REFL_A_RF45_I_YAW_OUT_DQ 0.997771 0.785327 0.607030 0.929066 0.882284 0.937111 0.684537 0.984272
H1:ASC-REFL_A_RF45_Q_YAW_OUT_DQ 0.945654 0.815915 0.738725 0.882462 0.976567 0.993592 0.537407 0.991905
H1:ASC-REFL_B_DC_YAW_OUT_DQ 0.999068 0.742474 0.031397 0.008371 0.031052 0.167697 0.038491 0.070031
H1:ASC-REFL_B_RF9_I_YAW_OUT_DQ 0.999382 0.461010 0.448559 0.823345 0.647265 0.888297 0.323946 0.987841
H1:ASC-REFL_B_RF9_Q_YAW_OUT_DQ 0.999599 0.643543 0.459728 0.772427 0.553919 0.841013 0.243502 0.955394
H1:ASC-REFL_B_RF45_I_YAW_OUT_DQ 0.998420 0.953713 0.271192 0.563421 0.766779 0.211379 0.886829 0.998096
H1:ASC-REFL_B_RF45_Q_YAW_OUT_DQ 0.988042 0.865125 0.415478 0.635645 0.289426 0.728005 0.838418 0.991842
H1:ASC-POP_A_YAW_OUT_DQ 0.995662 0.999210 0.988526 0.943128 0.435541 0.992223 0.871966 0.993443
H1:ASC-POP_B_YAW_OUT_DQ 0.996257 0.999320 0.971955 0.940216 0.319431 0.991293 0.911992 0.996432

Sensing matrix (complex)

Excitation: H1:ASC-INP1_Y_EXC H1:ASC-PRC1_Y_EXC H1:ASC-PRC2_Y_EXC H1:ASC-MICH_Y_EXC H1:ASC-SRC1_Y_EXC H1:ASC-SRC2_Y_EXC H1:ASC-DHARD_Y_EXC H1:ASC-CHARD_Y_EXC
Monitor channel: H1:ASC-INP1_Y_OUT_DQ H1:ASC-PRC1_Y_OUT_DQ H1:ASC-PRC2_Y_OUT_DQ H1:ASC-MICH_Y_OUT_DQ H1:ASC-SRC1_Y_OUT_DQ H1:ASC-SRC2_Y_OUT_DQ H1:ASC-DHARD_Y_OUT_DQ H1:ASC-CHARD_Y_OUT_DQ
H1:ASC-AS_A_DC_YAW_OUT_DQ 4.027209e-07 + 1.899337e-08i -6.253913e-09 + -5.391983e-07i 2.288100e-06 + 7.990791e-06i -1.737378e-06 + 2.298928e-06i 9.970103e-07 + -1.220431e-07i -3.298331e-06 + 1.496864e-07i -1.508166e-07 + 7.110860e-08i 1.422199e-08 + 5.477017e-09i
H1:ASC-AS_A_RF36_I_YAW_OUT_DQ 1.212717e-02 + 1.579448e-02i 3.751943e-02 + -8.985242e-03i -2.913908e-01 + -7.076751e-02i -2.472445e-01 + 2.061735e-01i -1.322697e-02 + -2.848534e-03i 1.366219e-02 + 2.228457e-02i 4.838004e-05 + 3.475343e-05i 1.461367e-06 + -2.636422e-06i
H1:ASC-AS_A_RF36_Q_YAW_OUT_DQ 6.193082e-03 + 8.024728e-03i 8.308821e-03 + 4.370276e-04i -5.859089e-02 + 7.496292e-03i -1.291612e-01 + 9.458192e-02i 5.299499e-04 + -1.471683e-03i -2.998403e-02 + 5.372998e-03i -2.257520e-04 + -1.351926e-04i 2.035940e-06 + 4.561889e-05i
H1:ASC-AS_A_RF45_I_YAW_OUT_DQ -1.106900e-03 + -1.239001e-03i -1.770337e-03 + 1.168462e-03i 4.923293e-03 + -4.170503e-03i 1.573156e-02 + -1.553507e-02i -1.447344e-03 + 9.727969e-04i 5.396046e-03 + -2.665830e-03i 7.231289e-04 + -5.450473e-04i -1.847234e-04 + 1.524634e-04i
H1:ASC-AS_A_RF45_Q_YAW_OUT_DQ 3.338836e-03 + -1.378019e-03i -5.265454e-04 + -3.143720e-03i 3.048349e-02 + 5.630679e-02i -1.485481e-02 + 1.101701e-02i 6.256012e-03 + -1.479746e-03i -1.980437e-02 + 1.992639e-03i -1.813056e-03 + 6.627589e-04i -6.409816e-05 + 4.123170e-04i
H1:ASC-AS_B_DC_YAW_OUT_DQ 1.461257e-07 + 9.761966e-08i 6.782250e-07 + -1.477519e-07i -7.024469e-06 + -4.161945e-06i 4.608787e-07 + -4.525432e-08i -1.071667e-06 + 1.429777e-07i -5.075450e-07 + -9.734776e-08i 1.095644e-07 + -4.887599e-08i 7.568048e-10 + -1.469667e-08i
H1:ASC-AS_B_RF36_I_YAW_OUT_DQ 3.204781e-03 + 2.887774e-03i -5.959230e-03 + 7.859582e-03i -2.801530e-02 + -2.812343e-02i -5.956846e-02 + 7.233699e-02i 2.381974e-03 + 8.900326e-04i 2.864792e-02 + 1.961192e-03i -2.172238e-04 + -1.174446e-04i -1.559346e-05 + 3.033324e-05i
H1:ASC-AS_B_RF36_Q_YAW_OUT_DQ 2.003745e-02 + 5.616267e-03i 1.835800e-02 + -1.275684e-02i -1.613873e-01 + 5.501185e-02i -1.121047e-01 + 1.414386e-01i -6.570962e-03 + -1.299065e-03i 2.710236e-02 + -8.189905e-05i 3.852000e-05 + -8.749586e-06i 8.448834e-06 + 1.858325e-05i
H1:ASC-AS_B_RF45_I_YAW_OUT_DQ 2.658061e-04 + 9.855628e-04i 9.948031e-04 + -3.611703e-05i -2.906763e-03 + -5.498778e-03i -1.155863e-02 + 1.032548e-02i 1.425911e-03 + -7.279870e-04i -4.509042e-04 + 2.772727e-03i -5.449907e-04 + 4.342962e-04i 1.579692e-04 + -1.402059e-04i
H1:ASC-AS_B_RF45_Q_YAW_OUT_DQ -9.145710e-04 + 1.013719e-03i 4.887684e-04 + 3.538828e-04i -2.033838e-02 + -1.530067e-02i 1.034215e-02 + -5.257066e-03i -6.722925e-03 + 1.378987e-03i 9.717521e-04 + -3.107270e-03i 1.459218e-03 + -6.064927e-04i 7.583010e-05 + -2.910549e-04i
H1:ASC-REFL_A_DC_YAW_OUT_DQ -5.860906e-05 + 5.633033e-06i 2.525165e-06 + -2.624554e-06i -8.568744e-07 + 4.788437e-06i -7.984156e-07 + -3.796204e-07i -1.069412e-08 + -5.606092e-08i 1.099525e-07 + -2.077054e-08i 3.289540e-10 + -1.891935e-09i -1.713573e-08 + -4.019022e-09i
H1:ASC-REFL_A_RF9_I_YAW_OUT_DQ -9.114679e-01 + 4.389823e-02i 3.058194e-02 + -3.550223e-02i -7.655207e-02 + 1.212435e-01i -2.045725e-02 + 1.791971e-02i -2.217381e-04 + -2.575830e-04i 2.933607e-03 + 9.105774e-04i -3.089962e-06 + 9.419621e-06i 3.028945e-04 + -1.190819e-04i
H1:ASC-REFL_A_RF9_Q_YAW_OUT_DQ -1.118313e-01 + 4.802969e-03i 1.243774e-03 + -3.856832e-03i 2.259966e-03 + 3.009054e-02i -2.081784e-03 + 1.854800e-03i 8.551393e-06 + 7.184424e-05i 6.137564e-04 + -7.245219e-05i 2.335265e-06 + -1.151488e-05i 7.971158e-05 + -2.342738e-05i
H1:ASC-REFL_A_RF45_I_YAW_OUT_DQ 3.223035e-01 + -1.587003e-02i 1.731560e-02 + -5.803764e-03i -1.951371e-01 + -5.439350e-02i -7.334375e-03 + 5.597870e-02i -1.390848e-03 + 1.330532e-03i 8.352473e-03 + 1.490413e-03i 1.525240e-05 + -6.462832e-06i -2.423681e-04 + 1.216301e-04i
H1:ASC-REFL_A_RF45_Q_YAW_OUT_DQ 7.133986e-02 + -8.361979e-04i 7.654021e-03 + 4.725196e-03i -1.584410e-02 + -1.052764e-01i -1.961981e-02 + -1.577263e-02i 1.332580e-03 + -2.052576e-03i 7.550922e-03 + -6.275144e-03i -3.783090e-06 + -1.497708e-06i -9.110278e-05 + 5.599862e-05i
H1:ASC-REFL_B_DC_YAW_OUT_DQ -7.049794e-05 + 5.612092e-06i 1.081151e-06 + -1.192442e-06i 3.360272e-06 + 8.986711e-07i 2.346302e-07 + -2.257806e-07i 4.108104e-08 + 2.208041e-08i 4.947713e-09 + -6.330364e-08i -1.548611e-09 + 2.554095e-10i 8.190983e-09 + -2.588118e-09i
H1:ASC-REFL_B_RF9_I_YAW_OUT_DQ 7.138949e-01 + -3.517070e-02i 5.926564e-03 + 1.264845e-02i -2.368256e-01 + -1.567026e-01i -3.877796e-02 + 2.239523e-02i -9.721380e-04 + -7.849731e-04i 1.722394e-03 + 2.907902e-03i 4.637671e-06 + -5.850533e-06i 3.044071e-04 + -1.671727e-04i
H1:ASC-REFL_B_RF9_Q_YAW_OUT_DQ 2.721447e-01 + -1.355046e-02i 8.572409e-04 + 5.613658e-03i -7.114326e-02 + -5.755532e-02i -1.124951e-02 + 5.909535e-03i -2.945575e-04 + -2.273787e-04i 3.641409e-04 + 9.058549e-04i 2.285760e-06 + -2.110506e-07i 5.901495e-05 + -3.637193e-05i
H1:ASC-REFL_B_RF45_I_YAW_OUT_DQ -2.841604e-01 + 1.709044e-02i 2.314298e-02 + -1.326939e-02i -4.648977e-02 + -3.468623e-02i -9.497930e-03 + -5.627392e-04i 2.922929e-04 + -3.893112e-04i -5.357178e-04 + 8.921423e-04i -4.154870e-06 + 1.701789e-05i -2.879682e-04 + 1.547613e-04i
H1:ASC-REFL_B_RF45_Q_YAW_OUT_DQ -2.074948e-02 + 1.756564e-03i 5.808172e-03 + -3.115659e-03i -3.450300e-02 + -6.994337e-03i -9.470159e-03 + 1.043970e-02i -4.149770e-04 + 5.438237e-05i 1.159381e-04 + 1.427145e-03i 1.278657e-06 + 5.460644e-06i -5.912523e-05 + 2.857588e-05i
H1:ASC-POP_A_YAW_OUT_DQ 2.328406e-07 + -7.252475e-09i 3.552911e-07 + -2.551209e-07i -7.090824e-07 + 4.413670e-08i -1.410812e-07 + 1.182249e-07i -2.361277e-09 + -2.638504e-09i 1.272490e-08 + 6.880929e-09i -1.507841e-10 + -2.653097e-10i 4.119425e-09 + -2.324956e-09i
H1:ASC-POP_B_YAW_OUT_DQ 1.612728e-07 + -1.976291e-08i 2.691307e-07 + -2.006345e-07i 4.065154e-07 + -3.562865e-08i 8.229263e-08 + -6.066842e-08i 1.615260e-10 + 1.524400e-09i -6.909220e-09 + -3.750446e-09i -1.708629e-11 + 2.474191e-10i -3.566622e-09 + 1.879124e-09i
GPS Times: 1109762803 1109762863 H1:ASC-INP1_Y_EXC 1109762884 1109762944 H1:ASC-PRC1_Y_EXC 1109762965 1109763026 H1:ASC-PRC2_Y_EXC 1109763047 1109763107 H1:ASC-MICH_Y_EXC 1109763128 1109763188 H1:ASC-SRC1_Y_EXC 1109763209 1109763270 H1:ASC-SRC2_Y_EXC 1109763291 1109763351 H1:ASC-DHARD_Y_EXC 1109763372 1109763432 H1:ASC-CHARD_Y_EXC