Displaying report 1-1 of 1.
Reports until 15:44, Saturday 07 March 2015
H1 IOO
gabriele.vajente@LIGO.ORG - posted 15:44, Saturday 07 March 2015 (17130)
IMC angular sensing matrix

This morning I measured the IMC angular sensing matrix, using the same script we used last night in full lock. The script is attached. I added to the list of signal the IMC transmitted power, just to see how large the coupling to RIN is. It turns out that for all angular lines, there is always good coherence of IMC transmission with all angular lines. This seems to indicate that the IMC is not very well aligned in the present configuration, intoducing an excess of RIN due to input jitter.

1109796196 1109796316 H1:SUS-MC1_M3_LOCK_P_EXC
1109796339 1109796459 H1:SUS-MC2_M3_LOCK_P_EXC
1109796482 1109796602 H1:SUS-MC3_M3_LOCK_P_EXC
1109796623 1109796743 H1:IMC-PZT_PIT_EXC

1109796832 1109796952 H1:SUS-MC1_M3_LOCK_P_EXC
1109796975 1109797095 H1:SUS-MC2_M3_LOCK_P_EXC
1109797117 1109797238 H1:SUS-MC3_M3_LOCK_P_EXC
1109797259 1109797379 H1:IMC-PZT_YAW_EXC

 

Pitch sensing matrix (abs)

Excitation: H1:SUS-MC1_M3_LOCK_P_EXC H1:SUS-MC2_M3_LOCK_P_EXC H1:SUS-MC3_M3_LOCK_P_EXC H1:IMC-PZT_YAW_EXC
Monitor channel: H1:SUS-MC1_M3_WIT_Y_DQ H1:SUS-MC2_M3_WIT_Y_DQ H1:SUS-MC3_M3_WIT_Y_DQ H1:IMC-PZT_YAW_OUT_DQ
H1:IMC-WFS_A_I_YAW_OUT_DQ 3.696414e+02 3.061484e+03 3.533718e+02 5.976158e+00
H1:IMC-WFS_B_I_YAW_OUT_DQ 4.455824e+02 4.345709e+02 4.161115e+02 2.648559e+01
H1:IMC-WFS_A_DC_YAW_OUT_DQ 1.042152e-01 8.690475e-02 9.141790e-02 2.336451e-03
H1:IMC-WFS_B_DC_YAW_OUT_DQ 1.674855e-01 4.350029e-01 1.492077e-01 5.357902e-04
H1:IMC-MC2_TRANS_YAW_OUT_DQ 3.081631e-03 7.946392e-03 3.053098e-03 2.193305e-06
H1:IMC-IM4_TRANS_YAW_OUT_DQ 1.713772e-03 1.209704e-02 4.963654e-04 6.413458e-06
H1:IMC-IM4_TRANS_SUM_OUT_DQ 2.359231e+00 1.977480e+01 2.686220e+00 4.085103e-03

Pitch coherence matrix

Excitation: H1:SUS-MC1_M3_LOCK_P_EXC H1:SUS-MC2_M3_LOCK_P_EXC H1:SUS-MC3_M3_LOCK_P_EXC H1:IMC-PZT_YAW_EXC
Monitor channel: H1:SUS-MC1_M3_WIT_Y_DQ H1:SUS-MC2_M3_WIT_Y_DQ H1:SUS-MC3_M3_WIT_Y_DQ H1:IMC-PZT_YAW_OUT_DQ
H1:IMC-WFS_A_I_YAW_OUT_DQ 0.869777 0.948594 0.830457 0.999963
H1:IMC-WFS_B_I_YAW_OUT_DQ 0.867195 0.942646 0.831500 0.999993
H1:IMC-WFS_A_DC_YAW_OUT_DQ 0.864768 0.936162 0.820782 0.999548
H1:IMC-WFS_B_DC_YAW_OUT_DQ 0.874447 0.948026 0.823632 0.995486
H1:IMC-MC2_TRANS_YAW_OUT_DQ 0.871487 0.949401 0.827857 0.996018
H1:IMC-IM4_TRANS_YAW_OUT_DQ 0.867652 0.948376 0.761663 0.999013
H1:IMC-IM4_TRANS_SUM_OUT_DQ 0.872150 0.947420 0.824094 0.396943

Pitch sensing matrix (complex)

Excitation: H1:SUS-MC1_M3_LOCK_P_EXC H1:SUS-MC2_M3_LOCK_P_EXC H1:SUS-MC3_M3_LOCK_P_EXC H1:IMC-PZT_YAW_EXC
Monitor channel: H1:SUS-MC1_M3_WIT_Y_DQ H1:SUS-MC2_M3_WIT_Y_DQ H1:SUS-MC3_M3_WIT_Y_DQ H1:IMC-PZT_YAW_OUT_DQ
H1:IMC-WFS_A_I_YAW_OUT_DQ 4.459577e+01 + -3.669414e+02i -1.996634e+03 + -2.320805e+03i -1.879244e+02 + -2.992592e+02i 5.880661e+00 + -1.064092e+00i
H1:IMC-WFS_B_I_YAW_OUT_DQ 5.306319e+01 + -4.424115e+02i -2.602883e+02 + -3.479969e+02i -2.355467e+02 + -3.430255e+02i 2.606789e+01 + -4.685228e+00i
H1:IMC-WFS_A_DC_YAW_OUT_DQ 1.130252e-02 + -1.036005e-01i 5.621075e-02 + 6.627810e-02i -5.307239e-02 + -7.443490e-02i -2.286895e-03 + 4.786584e-04i
H1:IMC-WFS_B_DC_YAW_OUT_DQ 1.795862e-02 + -1.665199e-01i -2.992772e-01 + -3.156907e-01i -8.665653e-02 + -1.214644e-01i -5.176168e-04 + 1.383617e-04i
H1:IMC-MC2_TRANS_YAW_OUT_DQ 1.854521e-04 + -3.076046e-03i 3.995685e-03 + 6.868744e-03i -1.790435e-03 + -2.473004e-03i 2.152887e-06 + -4.191235e-07i
H1:IMC-IM4_TRANS_YAW_OUT_DQ 1.813095e-04 + 1.704154e-03i -7.544133e-03 + -9.456444e-03i -1.952017e-04 + 4.563715e-04i 6.310659e-06 + -1.143692e-06i
H1:IMC-IM4_TRANS_SUM_OUT_DQ -4.775657e-01 + 2.310390e+00i 1.282324e+01 + 1.505347e+01i 1.318504e+00 + 2.340368e+00i -4.036933e-03 + 6.254901e-04i

Yaw sensing matrix (abs)

Excitation: H1:SUS-MC1_M3_LOCK_P_EXC H1:SUS-MC2_M3_LOCK_P_EXC H1:SUS-MC3_M3_LOCK_P_EXC H1:IMC-PZT_PIT_EXC
Monitor channel: H1:SUS-MC1_M3_WIT_P_DQ H1:SUS-MC2_M3_WIT_P_DQ H1:SUS-MC3_M3_WIT_P_DQ H1:IMC-PZT_PIT_OUT_DQ
H1:IMC-WFS_A_I_PIT_OUT_DQ 1.824749e+02 9.969352e+02 9.296137e+01 8.824289e+00
H1:IMC-WFS_B_I_PIT_OUT_DQ 2.089930e+02 1.633214e+02 1.684276e+02 3.478393e+01
H1:IMC-WFS_A_DC_PIT_OUT_DQ 3.358676e-02 1.675410e-03 2.499026e-02 5.706180e-03
H1:IMC-WFS_B_DC_PIT_OUT_DQ 2.348725e-02 3.278211e-02 1.059425e-02 1.922967e-03
H1:IMC-MC2_TRANS_PIT_OUT_DQ 1.085159e-02 1.349890e-02 8.725626e-03 6.492894e-06
H1:IMC-IM4_TRANS_PIT_OUT_DQ 2.917940e-03 1.666967e-02 2.089132e-03 1.232166e-06
H1:IMC-IM4_TRANS_SUM_OUT_DQ 2.401433e-01 1.461071e+00 2.081551e-01 1.118365e-02

Yaw coherence matrix

Excitation: H1:SUS-MC1_M3_LOCK_P_EXC H1:SUS-MC2_M3_LOCK_P_EXC H1:SUS-MC3_M3_LOCK_P_EXC H1:IMC-PZT_PIT_EXC
Monitor channel: H1:SUS-MC1_M3_WIT_P_DQ H1:SUS-MC2_M3_WIT_P_DQ H1:SUS-MC3_M3_WIT_P_DQ H1:IMC-PZT_PIT_OUT_DQ
H1:IMC-WFS_A_I_PIT_OUT_DQ 0.998794 0.999674 0.998379 0.999850
H1:IMC-WFS_B_I_PIT_OUT_DQ 0.998710 0.999385 0.998624 0.999997
H1:IMC-WFS_A_DC_PIT_OUT_DQ 0.998635 0.819492 0.998388 0.999944
H1:IMC-WFS_B_DC_PIT_OUT_DQ 0.998203 0.998185 0.997417 0.999615
H1:IMC-MC2_TRANS_PIT_OUT_DQ 0.998884 0.999698 0.999013 0.999613
H1:IMC-IM4_TRANS_PIT_OUT_DQ 0.998884 0.999685 0.998991 0.992295
H1:IMC-IM4_TRANS_SUM_OUT_DQ 0.992307 0.998904 0.992879 0.914613

Yaw sensing matrix (complex)

Excitation: H1:SUS-MC1_M3_LOCK_P_EXC H1:SUS-MC2_M3_LOCK_P_EXC H1:SUS-MC3_M3_LOCK_P_EXC H1:IMC-PZT_PIT_EXC
Monitor channel: H1:SUS-MC1_M3_WIT_P_DQ H1:SUS-MC2_M3_WIT_P_DQ H1:SUS-MC3_M3_WIT_P_DQ H1:IMC-PZT_PIT_OUT_DQ
H1:IMC-WFS_A_I_PIT_OUT_DQ 1.793732e+02 + 3.350152e+01i 9.213024e+02 + 3.808959e+02i 9.002523e+01 + 2.317919e+01i -8.696218e+00 + 1.497955e+00i
H1:IMC-WFS_B_I_PIT_OUT_DQ 2.046045e+02 + 4.260397e+01i 1.508551e+02 + 6.258276e+01i 1.623020e+02 + 4.501022e+01i -3.427992e+01 + 5.899923e+00i
H1:IMC-WFS_A_DC_PIT_OUT_DQ 3.297093e-02 + 6.402182e-03i 1.562560e-03 + 6.044878e-04i 2.419939e-02 + 6.237182e-03i -5.608380e-03 + 1.051930e-03i
H1:IMC-WFS_B_DC_PIT_OUT_DQ 2.309431e-02 + 4.278260e-03i 3.047612e-02 + 1.207776e-02i 1.025308e-02 + 2.666902e-03i -1.888483e-03 + 3.625377e-04i
H1:IMC-MC2_TRANS_PIT_OUT_DQ -1.066824e-02 + -1.986341e-03i -1.256634e-02 + -4.930250e-03i -8.460478e-03 + -2.134680e-03i -6.383825e-06 + 1.185096e-06i
H1:IMC-IM4_TRANS_PIT_OUT_DQ -2.875068e-03 + -4.983555e-04i -1.544016e-02 + -6.283254e-03i -2.027304e-03 + -5.044915e-04i 1.211130e-06 + -2.267084e-07i
H1:IMC-IM4_TRANS_SUM_OUT_DQ -2.307384e-01 + -6.654749e-02i -1.331904e+00 + -6.006321e-01i -1.954466e-01 + -7.161846e-02i 1.102574e-02 + -1.872702e-03i
Displaying report 1-1 of 1.