Displaying report 1-1 of 1.
Reports until 19:40, Friday 13 March 2015
H1 General (DetChar)
ryan.fisher@LIGO.ORG - posted 19:40, Friday 13 March 2015 - last comment - 09:25, Saturday 14 March 2015(17260)
ODC MEDM Screens Created and Settings Drafted for LSC, ASC and OMC
TJ Massinger, Ryan F.,

We created new MEDM screens for the new ASC and OMC ODC channels, and updated the screen for LSC.  These are in their appropriate common/medm/ directories.  The LSC_ODC.adl has not been committed to the SVN because the local directory is in a strange state.  Pictures attached!

We also took a first pass through setting all of the EPICs records for the LSC and ASC ODC channels.  These settings have been captured in the safe.snap files for the two models and committed to the SVN.
Images attached to this report
Comments related to this report
jameson.rollins@LIGO.ORG - 09:25, Saturday 14 March 2015 (17270)

I remind everyone that white is a forbidden color for MEDM screens, since that's the color they turn when they have lost contact with the server.

Displaying report 1-1 of 1.