Earlier in the evening we tripped the RMS watchdog on ETMX, and had to drive out the end station to power cycle the coil driver.
This wasn't obvious from the control room. Three things that would help are to
1) add this to the OPS overview screen
2) add it to the SYS_DIAG gaurdian
3) add it to the SUS guardians
They are now in SYS_DIAG.