The whistles in DARM are still quite prominent in this lock. As briefly summarized in this alog, they happen whenever the PSL VCO frequency crosses 79.2 MHz. This points to the likely cause. This is a reliable enough indicator that we can get some statistics. In the first hour of the current lock (Mar 27 9 UTC to 10 UTC), the whistles happen at a rate of 4 per minute.
Below are four spectrograms. The first two show some whistles identified this way. A new feature is that there seems to be a second oscillator very close by, or maybe some harmonic of the beat note. The next two spectrograms show a minute with several whistles, and the next minute where none occurred. Even when none go through zero frequency, you can still see the beat note hovering up near Nyquist.