J. Garcia, J. Kissel
The x1susquad.mdl
model on the X1 SUS Test Stand was modified to match the H2 ITMY model. The QUAD_MASTER.mdl
library part from '/opt/rtcds/tst/x1/cds_user_apps/trunk/sus/common/models/'
was imported and replaced the existing block in the x1susquad.mdl
. Major changes were the output OSEM drive channels were changed from "*OSEMOUTF_*" to "*COILOUTF_*". The X1SUSQUAD.ini file was also edited to include the *COILOUTF_* filters. The new watchdog AC-coupled & band-limited filters were also implemented as in the H2 ITMY watchdogs.
However, the Binary I/O channels and ISC input filters were terminated in the Test Stand model.
The model was re-compiled and "make installed" then the frontend rebooted to confirm changes. It's location is in:
'/opt/rtcds/tst/x1/cds_user_apps/trunk/sus/x1/models/x1susquad.mdl'
. The build location for the X1 Test Stand model is '/opt/rtcds/tst/x1/core/release/src/epics/simLink/'
. This location's "x1susquad.mdl" is linked to the actual model location above.
The x1 quad overview medm - '/opt/rtcds/tst/x1/cds_user_apps/trunk/sus/common/medm/quad/SUS_CUST_QUAD_OVERVIEW.adl'
- was also modified to macro-substitute the X1 Test Stand parameters. A new SITEMAP.adl was created for the X1 Test Stand. Its location is now in '/opt/rtcds/tst/x1/cds_user_apps/trunk/cds/x1/medm/X1SITEMAP.adl'
. It only has links to the X1 QUAD medm, but future revisions will include the BSFM and other suspension builds.