koji.arai@LIGO.ORG - posted 20:37, Sunday 29 March 2015 (17565)
M7.5 - 55km SE of Kokopo, Papua New Guinea / HEPI/ISI/SUS recovery

[Evan, Koji]

M7.5 - 55km SE of Kokopo, Papua New Guinea 2015-03-29 23:48:31 (UTC)

The EQ knocked off most of the HEPI/ISI/SUSs. The ground motion calmed down after a couple of hours.

The WDs were reset.

Current status:

- All of the HEPIs are in the "ROBUST_ISOLATED" mode.

- All of the HAM ISIs are in the "ISOLATED" mode.
  All of the BSC ISIs except for the BS ISI are in the "FULLY-ISOLATED" mode.
  BS-ISI is in the "ISOLATED_DAMPED" mode. (As it was like this, I left it so. If it is necessary to go to "ISOLATED", please do so.)

- All SUSs except for PRM and SRM are in the "ALIGNED" mode.
  PRM and SRM are in the "MISALIGNED" mode.
  WDs of the TTs were restored too.