Reports until 19:27, Tuesday 31 March 2015
H1 INJ (CAL)
jeffrey.kissel@LIGO.ORG - posted 19:27, Tuesday 31 March 2015 (17596)
CAL_INJ_MASTER Updated to Split TRANSIENT Injection Bank into BURST and CBC
J. Kissel, D. Macleod, J. Betzwieser
WP #5124

The hardware injection team wished to have separate filter banks for transient hardware injections -- one CBC and one for BURST -- to ease the automation of recording the information for later processing. There was previously only one called TRANSIENT. 

As such, Duncan modified the 
/opt/rtcds/userapps/release/cal/common/models/CAL_INJ_MASTER.mdl
library part, committed to the repo, that corner of which I updated, and recompiled, installed, and restarted the 
/opt/rtcds/userapps/release/cal/h1/models/h1calcs.mdl
front end model/code. 

Details:
- See attached screen shot for what the hardware injection corner of the h1calcs.mdl looks like now, with the update.
- The ODC vector for transient injections is now also split into BURST and CBC bits.
- This required a DAQ restart.
- I confirmed that there were no SDF system differences before restarting, so there was no need to capture a new safe SDF file.
- Since this was merely an update to the library part, there are no changes to the top-level model, so there's nothing to commit once finished.
Images attached to this report