H1 SEI
sheila.dwyer@LIGO.ORG - posted 01:02, Friday 03 April 2015 - last comment - 10:22, Friday 03 April 2015(17651)
HAM3 seismic problem

Evan, Sheila, Koji

We ran into some difficulty tonight with HAM3 seismic, both HEPI and the ISI are tripping.  We've tried several things:

Images attached to this report
Comments related to this report
jim.warner@LIGO.ORG - 10:22, Friday 03 April 2015 (17663)

It's a bad ADC. Richard is working on replacing it right now.

jeffrey.kissel@LIGO.ORG - 09:31, Friday 03 April 2015 (17658)
J. Kissel, J. Warner, R. McCarthy

Update: H3 IPS sensor died last night around 7:30 UTC (see attached screenshot). We went out to the pier, no obvious cable problems. We manually moved the HEPI pier, and saw all Horz. sensors register motion *except* H3. We swapped H3 and V3 cables, and the H3 sensor readout by the V3 channel registers the motion. So, we assume problems are upstream of the sensor in the pier pod / satellite box or further up. Richard and Jim continue to investigate. Stay tuned!
Images attached to this comment