Displaying report 1-1 of 1.
Reports until 09:21, Friday 03 April 2015
H1 PSL (PSL)
peter.king@LIGO.ORG - posted 09:21, Friday 03 April 2015 (17657)
PSL ISS REFSIGNAL ezcaservo
In order to try and keep the diffracted power at a nominal 8%, I tried a simple ezcaservo to do this.
Running the following on opsws2
ezcaservo -r "H1:PSL-ISS_DIFFRACTION_AVG" -s 8.0 -g -0.001 -f 0.05 -t 240 "H1:PSL=ISS_REFSIGNAL"
This timed out after 4 minutes.

Increasing the gain to -0.01 seems okay.  -0.1 is too high. -0.05 is too high.  -0.02 seems okay.

The attached plot shows two manually introduced excursions from the reference signal set point and
the recovery done by ezcaservo, which seems to work okay.  The final command issued was
ezcaservo -r "H1:PSL-ISS_DIFFRACTION_AVG" -s 8.0 -g -0.02 -f 0.05 -t 240 "H1:PSL-ISS_REFSIGNAL"

The command timed out and is no longer running.  It would be worth taking out for a longer test
drive at a later time.
Images attached to this report
Displaying report 1-1 of 1.