Evan, Sheila, Koji
We ran into some difficulty tonight with HAM3 seismic, both HEPI and the ISI are tripping. We've tried several things:
It's a bad ADC. Richard is working on replacing it right now.
J. Kissel, J. Warner, R. McCarthy Update: H3 IPS sensor died last night around 7:30 UTC (see attached screenshot). We went out to the pier, no obvious cable problems. We manually moved the HEPI pier, and saw all Horz. sensors register motion *except* H3. We swapped H3 and V3 cables, and the H3 sensor readout by the V3 channel registers the motion. So, we assume problems are upstream of the sensor in the pier pod / satellite box or further up. Richard and Jim continue to investigate. Stay tuned!