Reports until 17:16, Monday 06 April 2015
H1 CAL (CAL, ISC)
jeffrey.kissel@LIGO.ORG - posted 17:16, Monday 06 April 2015 (17710)
2015-04-06 H1 DARM (locked on ETMY) OLGTF After DCPD Compensation Change
J. Kissel, S. Dwyer

Sheila's taken another DARM open loop gain transfer function just a second ago at my request, such that we can get a handle on how much the loop (and therefore the calibration) has changed since Koji improved the DCPD compensation (see LHO aLOG 17647. I'll process and make a statement tomorrow but I record some details here for the record. 

Parameters needed for Kiwamu's bare-bones calibration model:
DARM Gain = +1300
DARM FMs ON = 1,2,3,4,5,6,7,9

ETMY UIM Gain = +0.2
UIM FMs = 1,2,3,5

The .xml has been copied over and committed to the calibration repository, here
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/PreER7/H1/Measurements/DARMOLGTFs/
2015-04-06_H1_DARM_OLGTF_LHOaLOG17710.xml
Non-image files attached to this report