daniel.sigg@LIGO.ORG - posted 15:07, Wednesday 08 April 2015 - last comment - 15:51, Wednesday 08 April 2015(17754)
RF Distribution

Looking at the RF distribution system for corner and end stations there are only 3 units which show an error:

There is also an error associated with the green WFS demodulators where the hardware for the readbacks is still in the works.

Comments related to this report
daniel.sigg@LIGO.ORG - 15:51, Wednesday 08 April 2015 (17756)

The 90MHz demod problem was traced to a crosswiring of the demod readbacks of ASAIR_A and ASAIR_B. Decided to swap the DB9 cables.