Displaying report 1-1 of 1.
Reports until 11:25, Thursday 02 April 2015
H1 SUS
betsy.weaver@LIGO.ORG - posted 11:25, Thursday 02 April 2015 - last comment - 22:06, Thursday 09 April 2015(17634)
SR2 Acceptance TFs

Attached are the Phase 3b damped and undamped TFs of SR2 taken over the last few months.

Note, there is only the damped M2 stage TF due to the fact that there is a broken coil o magne at that stage and I was leary of driving too hard or too much.

Non-image files attached to this report
Comments related to this report
stuart.aston@LIGO.ORG - 22:06, Thursday 09 April 2015 (17795)
Due to a scaling issue affecting lower stages of the suspension, these TFs have been re-processed, and are presented in LHO aLOG entry 17786.