Two Tip-tilts assembled for 40m

 

Two tip-tilts have been assembled for 40m.  They are sitting on the optics bench in the Optics lab.

These have thinner wire (43 microns in diameter) to avoid the hysterises seen in the thicker 125 micron wire.  Therefore these have to be handled more carefully.  The wires are quite unforgiving of any kinks or handling errors.

As agreed, these do not contain BOSEMs.  Type-B (one stage before the production line)  bosems will eventually be used in these.

The tip-tilts are ready for shipment to 40m.  They have been wrapped in Al-foil.  For long term storage, these have to be stored in a dry atmosphere to avoid rusting of the "piano wire" fibers.  The mirror holders are locked into place for shipment using the eddy current dampers on either side of the mirror mounts. 

The Sl nos are 007 and 038 (Bottom Plate).  Images of the assembled tip-tilts and their various reference numbers are attached. 

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 14:34, Friday 17 April 2015 (17933)

Correction:  s/n 34 will be sent to CIT (not 38).