Sheila, Alexa, Evan
We have recovered the usual low-noise locking state (except for the outstanding issue of the HAM6 centering scheme) and have turned up the power to 15 W.
As before, HV in HAM6 has been turned off for the night.
The DARM Open Loop Gain comparison was made with the script /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/PreER7/H1/Scripts/DARM_OLTFGTF_LHO_xx.m Now that it has an aLOG number, I've moved and committed the analysis script to /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/PreER7/H1/Scripts/DARM_OLTFGTF_LHO_LHOaLOG17835.m and I've downloaded the template, and saved and committed it to /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/PreER7/H1/Measurements/DARMOLGTFs/2015-04-13_H1_DARM_OLGTF_LHOaLOG17835.xml Stay tuned for more detailed analysis -- so excited we've got data out to 1 [kHz]! Other Notes: - Evan used the above result to scale the optical gain of the sensing function in the CAL-CS front-end calibration. (This was after we suddenly had 50 [Mpc] for a bit -- the optical gain had not been correctly compensated for that lock stretch. It's now been fixed, but again, stay tuned for further analysis to confirm.) - This model of the DARM loop -- which I just cleaned up and updated this Saturday (aLOG pending) -- do *not* include the either the analog or digital anti-imaging and anti-aliasing filters and includes a time delay or 440 [us], as was the case with the other case-by-case analysis scripts in that directory. - as with LHO aLOG 17834, the ETMY ESD linearization is OFF.