Displaying report 1-1 of 1.
Reports until 22:55, Monday 13 April 2015
H1 ISC (SUS)
sheila.dwyer@LIGO.ORG - posted 22:55, Monday 13 April 2015 (17854)
Angle to length coupling for ETMs, beam diverters, wind, rotation stage

Alexa, Sheila. Evan, Daniel Koji

Unfortunately, all of these promising developments happened during a lock where the ETMY ESD was tripped, untripping it breaks the lock.  Evan has edited the guardian so that it will not move past ALS unles the ESD is on, so this should not happen to us again.  

Sadly, the wind  started gusting to 30-35 mph while we were reseting the PUM watchdogs, and is forecast to stay that way for about 24 hours.  We have locked with these kind of windspeeds before, but today we are having difficulty, perhaps because the ground motion below 1 Hz was not small even before the wind started.  The BRS is on at end X with broad low frequency sensor correction, however this storm seems to be mostly along the Y direction.  Evan has also increased the common tidal bandwidth again (0.08 now).  We've ben keeping ALS locked for 10-15 minutes.  

Images attached to this report
Displaying report 1-1 of 1.