BSC-ISI ff match gains calculated and added

A while ago I wrote a script to calculate match gains for the BSC FF to match the ISI L4C's to the HEPI L4C's. This was based on Arnaud's script script to compute the match gains for the sensor correction, in alog 16208. The process was much the same, putting the St1 in 750mhz cps blends, turning off feedforward and sensor correction to the ISI and HEPI. I left the ISI's like that for 10 minutes, then calculated the transfer function between the HEPI and ISI L4C's, and took the average between .1 and .4 hz. The transfer functions all look somewhat like the attached one for the BS. Most match gains were are 1 +/-10%, but ETMY and the BS both had one value that was off by about 20%, X for ETMY, Y for the BS. Gains are installed, I'll get some performance data overnight. The script is in the SEISVN under /BSC-ISI/Common/Misc, it's called BSC_FF_gain_matching. You can see what the results look like by running (with the SEI paths loaded) BSC_FF_gain_matching('H1', 'ITMX', 1113079985, 600) and exchanging 'ITMX' for the other chambers.