Reports until 16:35, Tuesday 14 April 2015
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 16:35, Tuesday 14 April 2015 - last comment - 18:17, Tuesday 14 April 2015(17873)
CDS Maintenance Summary

H0:PEM rename to H1:PEM [WP5153, ECR1500016]

Patrick, Jim, Dave:

The EPICS PEM systems which monitor the weather stations and dust monitors had their channel names changed from the prefix H0:PEM- to H1:PEM-.

The DAQ was stopped and the minute trends were offloaded to a temporary location on the SSD raid. A new blank minute trend area was created. The new H1 INI files were loaded and the DAQ was restarted. Later the NDS servers were configured to serve the offloaded minute trends (in their temporary location). Later they will be migrated from SSD to HDD raids.

The EPICS IOCs for Weather and Dust were modfied and restarted. New H1 targets were created, and safe.snap files moved. MEDM screens were modified.

This WP will remain open to cover the remaining DAQ work which is needed.

End Station SUS/SEI upgrade to RCG2.9.1 [WP5154]

Jeff, Jim, Rolf, Dave:

RCG Tag 2.9.1 was installed on h1build. The following models were upgraded to this tag: h1iopsus[ex,ey], h1iopsei[ex,ey], h1susetm[x,y], h1sustms[x,y], h1hpietm[x,y], h1isietm[x,y]. No DAQ restart was required.

This closes WP5154, future WPs will cover upgrading the rest of H1.

3IFO storage environment monitoring

Richard, Filiburto, Dave, Jim:

The EPICS monitoring system for the LVEA 3IFO storage system was started today. The EPICS channels were added to the DAQ.

Comments related to this report
david.barker@LIGO.ORG - 18:17, Tuesday 14 April 2015 (17877)

moved the old H0 dust and weather target directories to target_archive/ so they don't show up in the hourly autoburt backups.