After today's upgrade to RCG 2.9.1 we looked to see if the DAC AUTOCAL was successful using these procedural notes. The last check was done on the BSCs only a few weeks ago (alog 17597). During today's check, we found errors on h1susb123 again and also on h1sush56. Both show that the AUTOCAL failed for 1 of their DACs. As well, Kissel logged into LLO and found all AUTOCALs reported SUCCESS on all SUS front ends since their last computer restart.
The LHO errors were as follows:
controls@h1sush56 ~ 0$ dmesg | grep AUTOCAL
[ 60.359217] h1iopsush56: DAC AUTOCAL SUCCESS in 5134 milliseconds
[ 65.510812] h1iopsush56: DAC AUTOCAL SUCCESS in 5134 milliseconds
[ 70.661410] h1iopsush56: DAC AUTOCAL SUCCESS in 5134 milliseconds
[ 75.813017] h1iopsush56: DAC AUTOCAL FAILED in 5134 milliseconds
[ 80.963620] h1iopsush56: DAC AUTOCAL SUCCESS in 5134 milliseconds
[8443363.521348] h1iopsush56: DAC AUTOCAL SUCCESS in 5134 milliseconds
[8443368.669944] h1iopsush56: DAC AUTOCAL SUCCESS in 5133 milliseconds
[8443373.818544] h1iopsush56: DAC AUTOCAL SUCCESS in 5133 milliseconds
[8443378.967145] h1iopsush56: DAC AUTOCAL FAILED in 5133 milliseconds
[8443384.115739] h1iopsush56: DAC AUTOCAL SUCCESS in 5133 milliseconds
The first of the 2 above calibrations was the reboot 97 days ago, on Jan 14, 2015 when we upgraded to RCG 2.9.
________________________________________________________________
controls@h1susb123 ~ 0$ dmesg | grep AUTOCAL
[ 61.101850] h1iopsusb123: DAC AUTOCAL SUCCESS in 5134 milliseconds
[ 66.252460] h1iopsusb123: DAC AUTOCAL SUCCESS in 5134 milliseconds
[ 71.833569] h1iopsusb123: DAC AUTOCAL SUCCESS in 5133 milliseconds
[ 77.416848] h1iopsusb123: DAC AUTOCAL SUCCESS in 5134 milliseconds
[ 82.567454] h1iopsusb123: DAC AUTOCAL SUCCESS in 5134 milliseconds
[ 87.718046] h1iopsusb123: DAC AUTOCAL SUCCESS in 5134 milliseconds
[ 92.869668] h1iopsusb123: DAC AUTOCAL SUCCESS in 5134 milliseconds
[ 98.021279] h1iopsusb123: DAC AUTOCAL FAILED in 5134 milliseconds
[6643697.827654] h1iopsusb123: DAC AUTOCAL SUCCESS in 5134 milliseconds
[6643702.976255] h1iopsusb123: DAC AUTOCAL SUCCESS in 5133 milliseconds
[6643708.553386] h1iopsusb123: DAC AUTOCAL SUCCESS in 5134 milliseconds
[6643714.130498] h1iopsusb123: DAC AUTOCAL SUCCESS in 5134 milliseconds
[6643719.278911] h1iopsusb123: DAC AUTOCAL SUCCESS in 5133 milliseconds
[6643724.427687] h1iopsusb123: DAC AUTOCAL SUCCESS in 5134 milliseconds
[6643729.576295] h1iopsusb123: DAC AUTOCAL SUCCESS in 5133 milliseconds
[6643734.724703] h1iopsusb123: DAC AUTOCAL FAILED in 5133 milliseconds
[8443632.920341] h1iopsusb123: DAC AUTOCAL SUCCESS in 5133 milliseconds
[8443638.069031] h1iopsusb123: DAC AUTOCAL SUCCESS in 5133 milliseconds
[8443643.646215] h1iopsusb123: DAC AUTOCAL SUCCESS in 5134 milliseconds
[8443649.223336] h1iopsusb123: DAC AUTOCAL SUCCESS in 5134 milliseconds
[8443654.371885] h1iopsusb123: DAC AUTOCAL SUCCESS in 5133 milliseconds
[8443659.520452] h1iopsusb123: DAC AUTOCAL SUCCESS in 5134 milliseconds
[8443664.669135] h1iopsusb123: DAC AUTOCAL SUCCESS in 5133 milliseconds
[8443669.817631] h1iopsusb123: DAC AUTOCAL FAILED in 5133 milliseconds
The first of the 3 above calibrations was the reboot 97 days ago, on Jan 14, 2015 when we upgraded to RCG 2.9, then a restart/calibration by Kissel April 1 (mentioned above), then today's RCG 2.9.1 upgrade.