Displaying report 1-1 of 1.
Reports until 17:42, Tuesday 21 April 2015
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 17:42, Tuesday 21 April 2015 (17992)
CDS maintenance Summary

RCG2.9.1 upgrade [WP5158]

Daniel, Betsy, Jeff, Jim, Dave:

we upgraded all H1 models to RCG tag version 2.9.1 this morning. The H1.ipc file was created from scratch, which removed 24 obsolete IPC channels. Daniel performed an ODC common model change. The end stations models were restarted several times to resync to the ipc file. Some duplicate channels were found in the end station CAL models, these were resolved with explicit EX,EY naming.

h1psliss model core dumped during an SDF table load. More details in earlier posting. We tried to reproduce this error on the DTS x1psl0 ISS model, were unable to do so.

Two 18bit DACs were discovered to have failed their autocal, details in earlier posting.

PSL ODC update [WP5157]

Dave:

The ODC component of the h1psliss model was modified: EPICS part of CHANNEL_OUTMON changed to unsigned integer part, CHANNEL_OUT data type changed to UNIT32. Change went in when PSL was restarted today, this closed WP5157.

I checked that all fast ODC DQ channels in the DAQ are now of data type 7 (unsigned integer 32 bit)

The rather lengthy restart log is attached

Non-image files attached to this report
Displaying report 1-1 of 1.