Aidan, Elli, Nutsinee
Following up Elli's alog 17993
I took advantage of a ~9:30 lock loss this morning to rotate the CO2X rotation stage around (the operator was informed). It took longer than I expected so I accidentally worked through as the Guardian was building up IR power (if you see something weird during 9:30-9:50 that could have been me. Sorry...)
Procedure: I requested the rotation stage to search for home, then requested a power of 0.212 W (nominal). Then repeatedly go to minimum and request the same power again to see if the rotation stage accumulate some error in angles. Eventually, I searched for home again a couple times then brought the power back to nominal.
Result: I find the result quite puzzling and need some times to think about it, but it seems like after search for home the difference between the requested power and the output power grows significantly. However, after a few adjustment I managed to get the requested nominal power and the output power to agree within 1% and that's where it was left this morning.
| Action | Requested Power (W) | Measured Angle (deg) | Measured Power out (W) | |Power out - Requested power| (W) | Note |
|
Search for home |
0 | 5.073 | |||
|
Request power |
0.212 | 43.92 | 0.245 | 0.035 (off by 16.5% of the requested power) | |
|
Go to minimum |
37.98 | -0.035 | |||
|
Request power |
0.212 | 43.95 | 0.248 | 0.037 (off by 17.4% of the requested power) | |
|
Go to minimum |
38.07 | -0.027 | Didn't wait until the output power settle | ||
|
Request power |
0.212 | 44.04 | 0.259 | 0.047 (off by 22.2% of the requested power) | |
|
Go to minimum |
38.09 | -0.034 | |||
|
Request Power |
0.212 | 44.06 | 0.264 | 0.052 (off by 24.5% of the requested power) | |
|
Go to minimum |
38.13 | -0.037 | |||
|
Request Power |
0.212 | 43.87 | 0.246 | 0.034 (off by 16.0% of the requested power) | |
|
Go to minimum |
38.01 | -0.036 | |||
|
Request Power |
0.212 | 43.92 | 0.246 | 0.034 (off by 16.0% of the requested power) | |
|
Search for home |
0 | 5.080 | |||
|
Request Power |
0.212 | 43.96 | 0.271 | 0.059 (off by 27.8% of the requested power) | |
|
Search for home |
0 | 5.054 | |||
|
Request Power |
0.212 | 44.15 | 0.306 | 0.094 (off by 44 % of the requested power) | |
|
Go to minimum |
38.24 | -0.035 | |||
|
Request Power |
0.212 | 43.94 | 0.257 | 0.045 (off by 21.2% of the requested power) | |
|
Request Power |
0.198 | 44.17 | 0.288 | 0.09 (off by 45.5% of the requested power) | |
|
Request Power |
0.178 | 44.00 | 0.260 | 0.082 (off by 46% of the requested power) | |
|
Request Power |
0.119 | 43.64 | 0.236 | 0.117 (off by 98% of the requested power) | |
|
Request Power |
0.149 | 42.42 | 0.140 | 0.009 (off by 6% of the requested power) | |
|
Request Power |
0.159 | 43.26 | 0.198 | 0.039 (off by 24% of the requested power) | |
|
Request Power |
0.169 | 43.10 | 0.169 | 0 (off by 0% of the requested power) | |
|
Request Power |
0.179 | 43.66 | 0.207 | 0.028 (off by 15.6% of the requested power) | |
|
Request Power |
0.189 | 43.57 | 0.180 | 0.009 (off by 4.8% of the requested power) | |
|
Request Power |
0.210 | 43.97 | 0.212 | 0.002 (off by 0.9% of the requested power) | Nominal |