Reports until 09:44, Friday 24 April 2015
H1 CDS
david.barker@LIGO.ORG - posted 09:44, Friday 24 April 2015 (18044)
possible inconsistent filter loading on h1omc model

Jim, Jeff, Dave

The h1omc model GDS_TP screen was showing a "Modified file" warning for H1OMC.txt filter module file. I checked and found the chans/H1OMC.txt and chans/filter_archive/h1omc/H1OMC_1113901380.txt files are in fact identical. Since the modification time of H1OMC.txt and the time of load were within the same minute, we think perhaps the Load Coefficient button was pressed too quickly after the file change and the front end computer suffered NFS cache lag. To clear up any confusion, Jeff has reloaded the filter file on h1omc.