Displaying report 1-1 of 1.
Reports until 17:05, Monday 27 April 2015
H1 GRD
thomas.shaffer@LIGO.ORG - posted 17:05, Monday 27 April 2015 - last comment - 17:56, Monday 27 April 2015(18081)
New 'OFFLINE' state added to IMC_LOCK

(This will not be reloaded into the working untill the morning)

As per request, I added a new 'OFFLINE' state to the IMC_LOCK Guardian.

This state will disengage the Common Mode Servo Board inputs (H1:IMC-REFL_SERVO_IN1EN and H1:IMC-REFL_SERVO_IN2EN) and misalign MC2.

Upon exiting this state, it will reengage the inputs and realign MC2 before heading through the DOWN state to aquire lock again, if desired.

Comments related to this report
thomas.shaffer@LIGO.ORG - 17:06, Monday 27 April 2015 (18086)

New graph attached

Images attached to this comment
jameson.rollins@LIGO.ORG - 17:56, Monday 27 April 2015 (18088)

I'm looking at the code changes here (which I had to do by logging into the site, since they haven't been committed to the SVN) and I see some issues that will likely prevent it from working as intended.

TJ: I suggest you talk to me before you try to deploy this.

Displaying report 1-1 of 1.