Displaying report 1-1 of 1.
Reports until 10:38, Tuesday 28 April 2015
H1 CDS (ISC)
david.barker@LIGO.ORG - posted 10:38, Tuesday 28 April 2015 (18095)
ALS models compiled against RCG branch-2.9 with rfm_delay flag

Jeff, Jim, Dave [WP5174]

h1alsey and h1alsex were rebuilt against RCG branch-2.9 (all other models are built against RCG tag-2.9.1). The new rfm_delay flag is turned ON for these two models. This should eliminate the RFM IPC receive errors seen by the h1asc model. I verified that all RFM IPC channels sent by the ALS models are only received by the ASC model.

I have disabled the cron job which was performing a DIAG_RESET on the h1asc model every minute. If we get any IPC errors on the ASC they will latch ON.

I have updated the model_info.txt file (lists all running models and their DCUID number). I have regenerated the H1CDS_FE_RCG_VERSIONS_CUST.adl MEDM screen (attached). All models are running 3994 except ALS which are running 3999. Later builds show a modified RCG (3994M and 3999M) reflecting a change in the standard environment scripts to add ALS and CAL to the RCG model search path.

Images attached to this report
Displaying report 1-1 of 1.