Updated CAL-INJ Library Part in CAL-CS Model, Added ODC Master IPC Connection
J. Kissel

In order to get the latest and greatest hardware injection infrastructure from LLO (for the ODC part, see LLO aLOG 17911), I've 
- svn updated the hardware injections library part,
/opt/rtcds/userapps/release/cal/common/models/CAL_INJ_MASTER.mdl
- added an SHMEM IPC sender called H1:CAL-INJ_ODC_IPC to the top level of
/opt/rtcds/userapps/release/cal/h1/models/h1calcs.mdl
- svn updated the library part
/opt/rtcds/userapps/release/sys/common/models/ODC_MASTER_PARTS_V2.mdl
- added an SHMEM IPC receiver called H1:CAL-INJ_ODC_IPC to the top level of
/opt/rtcds/userapps/release/sys/h1/models/h1odcmaster.mdl
and connected it to the last input
- compiled, installed, and restarted both models
- committed the top-level models to their respective location in the svn.

This closes WP 5172.