Log of today's hardware injections

M. Landry, J. Kissel

We injected the same CBC waveform on fourteen occasions with a variety of gains, into the DC locked machine.  The strain waveform is a 1.4-1.4 solar mass BNS coalescence, optimally-oriented, at 45Mpc (the same waveform injected into L1 during ER6). Below we summarize these injections:

Channel = H1:CAL-INJ_TRANSIENT_EXC

Waveform: /ligo/home/jeffrey.kissel/2015-04-30/injection_strain.txt

Logfiles: /ligo/home/jeffrey.kissel/2015-04-30/*.log

gps time

utc time  scalar gain
1114538072 May 01 2015 17:54:16 UTC 1.0
1114538434 May 01 2015 18:00:18 UTC 2.0
1114538619 May 01 2015 18:03:23 UTC 10.0
1114539102 May 01 2015 18:11:26 UTC 10.0
1114539462 May 01 2015 18:17:26 UTC 10.0
1114540301 May 01 2015 18:31:25 UTC 50.0
1114540790 May 01 2015 18:39:34 UTC 50.0
1114541450 May 01 2015 18:50:34 UTC 10.0
1114543037 May 01 2015 19:17:01 UTC 10.0
1114543403 May 01 2015 19:23:07 UTC 2.0
1114543833 May 01 2015 19:30:17 UTC 1.0
1114544201 May 01 2015 19:36:25 UTC 0.1
1114544554 May 01 2015 19:42:18 UTC 0.01