Stochastic Hardware Injection Started with 0.1x Amp at 23:29 UTC
J. Kissel, E. Daw

In this current lock stretch, I've begun Ed's Stochastic Injection (LHO aLOG 18161) starting at 23:29 UTC. Scared of breaking the lock, I've started with multiplying the whole injection by a scale factor of 0.1. Out of habit, this has gone through the H1:CAL-INJ_TRANSIENT bank instead of the H1:CAL-INJ_CW bank, but signals arising from both banks should result in identical DARM CTRL [ct]. It should last ~10 minutes. The observation intent bit is on.
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 17:17, Saturday 02 May 2015 (18185)
This injection completed as scheduled. It also reduced our inspiral range by 3 [Mpc]. I'm glad I decreased the amplitude by a factor of 10!

Details:
I ran the following command from the 
/ligo/home/jeffrey.kissel/2015-05-02/
directory on the hardware injection machine, h1hwinj1:
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 inj10mins.txt 0.1 -d -d > 2015-05-02_2327UTC_InjectionTest_x0p1.log

Here're the exact start and stop times:
Channel = H1:CAL-INJ_TRANSIENT_EXC
File    = /ligo/home/jeffrey.kissel/2015-05-02/inj10mins.txt
Scale   =          0.100000
Start   = 1114644525.000000
End     = 1114645111.000000
Duration= 586 [sec]

I attach the output of the .log file (renamed to .txt because the aLOG can't handle the ".log" extension).