Reports until 15:52, Friday 08 May 2015
H1 CDS
james.batch@LIGO.ORG - posted 15:52, Friday 08 May 2015 - last comment - 17:36, Saturday 09 May 2015(18333)
Remote control power switch installed for HWS camera at EY
A remote controlled power switch has been installed at EY to allow power for the HWS camera to be turned off or on from the control room.  The IP address for the switch is 10.105.0.155, access using telnet, port 23.  Ellie King has the instructions for controlling the power.  The camera is plugged in to outlet #1.
Comments related to this report
eleanor.king@LIGO.ORG - 17:36, Saturday 09 May 2015 (18344)

The HWS is plugged into outlet J1.  To turn on the power type into a terminal:

 

telnet 10.105.0.155 23          (open telnet)

@@@@                                   (start IPC)

?                                                (brings up help scrren with list off commands)

A10                                           (turns on all power outlets.  "A00"  turns them all off.

LO                                             (logs out)

^]                                               (close telnet)