Displaying report 1-1 of 1.
Reports until 09:36, Monday 11 May 2015
H1 PSL (DetChar, PSL)
edmond.merilh@LIGO.ORG - posted 09:36, Monday 11 May 2015 (18353)
PSL Weekly Report
Laser Status: 
SysStat is good
Front End power is 31.8W (should be around 30 W)
FRONTEND WATCH is RED
HPO WATCH is RED

PMC:
It has been locked 0 day, 17 hr 30 minutes (should be days/weeks)
Reflected power is 2.4 Watts  and PowerSum = 24.4 Watts.
(Reflected Power should be <= 10% of PowerSum)

FSS:
It has been locked for 1 h and 28 min (should be days/weeks)
TPD[V] = .93V (min 0.9V)

ISS:
The diffracted power is around 7.8% (should be 5-9%)
Last saturation event was 1 h and 29 minutes ago (should be days/weeks)