Following up what reported by Jeff about the DARM pole frequency, the attached plot shows a simulation of the change in the pole frequency when the SRM is misligned. To move the pole down to 290 Hz we would need a misalignment of about 30 microradians. It seems a large misalignment to me, but at least in simulation it's not affecting much the error signals or the power buildups.
Last night, engaging the error point offset gave about 8 µrad of tilt in SRM yaw. Calibration of SRM M1 yaw is 2.7 ct of drive per microradian, according to the alignment sliders.