Displaying report 1-1 of 1.
Reports until 15:30, Thursday 14 May 2015
H1 ISC (CAL, ISC)
gabriele.vajente@LIGO.ORG - posted 15:30, Thursday 14 May 2015 - last comment - 16:37, Thursday 14 May 2015(18432)
DARM pole frequency vs SRM tilt

Following up what reported by Jeff about the DARM pole frequency, the attached plot shows a simulation of the change in the pole frequency when the SRM is misligned. To move the pole down to 290 Hz we would need a misalignment of about 30 microradians. It seems a large misalignment to me, but at least in simulation it's not affecting much the error signals or the power buildups.

Images attached to this report
Comments related to this report
evan.hall@LIGO.ORG - 16:37, Thursday 14 May 2015 (18435)

Last night, engaging the error point offset gave about 8 µrad of tilt in SRM yaw. Calibration of SRM M1 yaw is 2.7 ct of drive per microradian, according to the alignment sliders.

Non-image files attached to this comment
Displaying report 1-1 of 1.