H1 CDS
david.barker@LIGO.ORG - posted 17:56, Tuesday 19 May 2015 (18516)
IO Chassis report

Richard, Jim, Dave:

We programmed all the remaining IO Chassis timing slave FPGA's today. In the morning we did MY and EY. This afternoon Jim did all the corner station chassis (SUS, SUSAUX, SEI, PSL, ISC)

We replaced all18bit DAC cards with new firmware versions in: h1susey, h1susb123, h1sush2a, h1sush34. Remaining SUS to do, h1sush56, h1sush2b. We have enough modified cards to do h1sush56 tomorrow, using the one card which fails on autocal* for the OMC DAC.

We had to shuffle some DAC cards around to make space for the new DC power supply. Details will be posted tomorrow.

We powered up all frontends. There is a problem with h1seib3, looks like the 16chan Contec BIO card is not being seen by the front end (it was in the slot we needed to use for the DC power supply). Will fix this tomorrow.

Some FECs have large positive IRIG-B values which will eventually come back down.

 

* 18-bit DAC card S/N 101208-05 fails its autocal. I replaced its firmware chipset and re-tested on DTS, it still fails. Jeff and Dan H suggest for now we install on h1sush56 for the OMC drive.