On-going cleanup of SDF

1)  Found that the ETMx misaligned offsets were changed at 9am on Monday morning.  H1:SUS-ETMX_M0_TEST_P_OFFSET went from -107 to -307 suspiciously.  The YAW offset only changed by 10e-3 which is negligable.

No alogs as to why, and Kiwamu agrees that they should be set back to what they were last week.  Since the decimal places went out to the 10e-8 place unnecessarly, I've rounded to 10e-1.

2)  I zeroed a bunch of large +/- 20000 offsets that were loaded (but not turned on) in the ETMY COILOUTF OFFSETS.  Also, un-alogged as to why they were there - likely testing left over from last week??

3)  Ignored new DAMP MODE TRAMP channels all ETM/ITMs.

4)  Accepted new weekend DAMP MODE filtering on ETM/ITMs.  These likely will keep popping up but now should be set to NOT MON since commissiones have written these into GRD over the weekend.