Reports until 11:35, Tuesday 26 May 2015
H1 CDS (SEI)
james.batch@LIGO.ORG - posted 11:35, Tuesday 26 May 2015 (18619)
Replaced power supply in h1seih45 I/O Chassis
Richard, Dave

After a failure over the weekend in which DAC and ADC cards could not be detected in the I/O chassis (alog 18603), we replaced the power supply.  The removed supply will be installed in the DAQ test stand for testing.